background image

Installation Guide

M-Series

Summary of Contents for M-Series

Page 1: ...Installation Guide M Series ...

Page 2: ... FLIR Systems Inc 6769 Hollister Ave Goleta CA 93117 www flir com maritime Support email MaritimeCameraSupport flir com Proper Disposal of Electrical and Electronic Equipment EEE The European Union EU has enacted Waste Electrical and Electronic Equipment Directive 2002 96 EC WEEE which aims to prevent EEE waste from arising to encourage reuse recycling and recovery of EEE waste and to promote envi...

Page 3: ...ra Installations 10 Physical Installation 11 Installing the Camera Unit 11 Installing the Joystick Control Unit JCU 12 Electrical Connections 13 Installing Noise Suppression Ferrites 13 Proper Grounding 14 Connecting Power 14 Video Connections 15 Ethernet Connections 15 M Series Reference Introduction 16 M Series Maintenance 16 Cleaning the JCU 16 Cleaning the Camera Optics 16 Camera Body Cleaning...

Page 4: ...ves image stability The stabilization feature compensates for the motion of the vessel and improves the utility of the camera video output when operating in rough seas or swell conditions For a complete list of models and a comparison of key features see Feature Comparison of M Series Models pg 20 This manual includes information about the following topics Installation overview Mounting the camera...

Page 5: ... has been disabled before cleaning surfaces that can cause pinch hazards Do not open the M Series camera unit for any reason Disassembly of the camera including removal of the cover can cause permanent damage and will void the warranty Be careful not to leave fingerprints on the M Series camera optics The M Series requires a power supply of 12 Vdc to 24 Vdc nominal 50 watt maximum Absolute voltage...

Page 6: ...ation These items are available in standard lengths through FLIR Systems Inc Electrical wire for system power up to 30 5 meters 100 feet 3 conductor gauge determined by cable length and supply voltage see Electrical Connections pg 13 for details Camera grounding strap Additional coaxial RG59 U video cables if required F style connector at the camera end Ethernet cables if required up to 100 meters...

Page 7: ...s center line as possible so you will have a symmetrical view of on coming traffic obstacles and other navigational hazards The M Series camera has a forward direction adjustment which has been set at the factory This is the direction directly toward the front of the vessel Icons on the video show the direction the camera is facing in relation to an outline of a ship After installation the forward...

Page 8: ...isassembling the camera will compromise the seals and will void the warranty Top Down Installation Kit If it is not possible to access the space on the other side of the mounting surface you can mount the camera using the top down mounting accessory kit This type of installation makes use of a mounting riser an optional accessory available from FLIR Systems Inc To install using the mounting riser ...

Page 9: ... Prior to Cutting Drilling Holes Determine if any interior trim panels must be removed in order to gain access to the mounting hardware and remove them ahead of time When selecting a mounting location for the M Series consider cable lengths and cable routing Ensure the cables are long enough given the proposed mounting locations and cable routing requirements and route the cables before you instal...

Page 10: ...he M Series ICD FLIR Doc 432 0003 XX YY for interconnect diagrams showing several possible system configurations using more than one JCU The following diagrams show dual payload system configurations using a customer supplied PoE switch and a separate monitor for each video signal Dashed lines represent connection to power Ethernet Video VIS IR JCU Customer supplied monitors PoE switch Noise suppr...

Page 11: ...ly relative to the bow of the vessel observe that the forward direction is reversed for a ball down installation If the template is printed be sure it is printed to scale so the dimensions are correct If you are using the top down installation kit the riser itself should be used as a template for the location of the drill holes and cable access hole Install the six 6 threaded studs into the base o...

Page 12: ...e JCU enclosure is rated IPX6 above the JCU mounting surface gasket Caution Standard JCU Mounting Instructions 1 Using the JCU template supplied as a guide in FLIR Doc 432 0003 XX YY mark the location of the rectangular opening that will allow the JCU to be recessed in the vessel s control console Ensure the corners are marked precisely and cut square 2 Apply the adhesive side of the rubber gasket...

Page 13: ...ration the clamp foot faces the rear of the mounting surface and allows the clamp to contact thinner panel surfaces while still allowing for proper compression of the JCU mounting gasket to form a watertight seal Electrical Connections Watertight connectors enclosures should be used on each of the electrical connections Table 1 1 shows the connections for the cables attached to the camera Installi...

Page 14: ...r cable wires that are sufficient size gauge or diameter for the supply voltage and total load camera and length of cable TABLE 1 1 Connections Quick Reference Cable Label Wire Comment Power Red Nominal 12 Vdc 24 Vdc Absolute range 10 Vdc to 32 Vdc 50 watt maximum Black DC return Green Chassis ground IR F Style Coax Thermal camera video only VIS IRa a VIS IR cable is only present on dual payload m...

Page 15: ...er video cable using an optional F type female to female adapter For cable runs in excess of 100 feet a video amplifier should be used Ethernet Connections The Ethernet cable from the camera can be connected to another Ethernet cable with the included RJ45 waterproof enclosure connector FLIR PN 4115028 The Ethernet network cable should be rated for use with PoE devices IEEE802 3af and should be 8 ...

Page 16: ...care should be used with your camera s optics They are delicate and can be damaged by improper cleaning The M Series thermal camera lenses are designed for the harsh outdoor environment and have a coating for durability and anti reflection but may require cleaning occasionally FLIR Systems Inc suggests that you clean the lens when image quality degradation is noticed or excessive contaminant build...

Page 17: ...o not attempt to repair it yourself The M Series camera is a sealed unit and can not be opened or serviced in the field Consult your installation dealer or FLIR Systems Inc for repair information Specifications Table 1 1 lists details about physical characteristics power usage and environmental features of your M Series camera The M Series is sealed at the factory against liquid water suspended pa...

Page 18: ...emale Outdoor http www scte org IEC 60169 24 Radio frequency coaxial connectors with screw coupling typically for use in 75 Ohm cable distribution systems Type F IEC 60945 Maritime navigation and radio communication equipment and systems general requirements IEC 60529 Degrees of Protection Provided by Enclosures IPX6 IEC 60068 Basic Environmental Testing Procedures Part 2 Tests 89 336 EEC Electrom...

Page 19: ...f View FPS Frames per Second refresh rate HFoV Horizontal Field of View ICD Interface Control Document IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IP Internet Protocol IR Infrared or thermal JCU Joystick Control Unit LCD Liquid Crystal Display LWIR Long wave infrared MFD Multifunction display NMEA National Marine Electronics Association NTSC...

Page 20: ...to 4x M 625S 432 0003 64 00S Single NTSC Yes No 640 x 480 9 Hz Yes 25 to 4x 432 0003 64 00 Single NTSC Yes No 640 x 480 30 Hz Yes 25 to 4x 432 0003 65 00Sa Single NTSC Yes No 640 x 480 9 Hz Yes 25 to 4x 432 0003 65 00a Single NTSC Yes No 640 x 480 30 Hz Yes 25 to 4x M 324CS 432 0003 62 00S Dual NTSC Yes Yes 336 x 256 9 Hz Yes 24 to 4x 432 0003 62 00 Dual NTSC Yes Yes 336 x 256 30 Hz Yes 24 to 4x 4...

Page 21: ... ft 4115028 Connector RJ45 Waterproof Enclosure 500 0393 00 Deluxe Dual Station Accessory Kit for M Series Includes Joystick Control Unit with weather cover 25 Shielded Ethernet cable RJ 45 25 Video Cable 50 Video Cable Video Amplifier splitter Qty 2 12V Power over Ethernet injector and mounting hardware 500 0394 00 Standard Dual Station Accessory Kit for M Series Includes Joystick Control Unit wi...

Page 22: ...port email MaritimeCameraSupport flir com EUROPE Eurasian Headquarters FLIR Systems CVS BV Charles Petitweg 21 4847 NW Teteringen Breda Netherlands PH 31 0 765 79 41 94 FX 31 0 765 79 41 99 flir flir com FLIR Systems Inc Corporate Headquarters FLIR Systems Inc 27700 SW Parkway Ave Wilsonville OR 97070 USA PH 1 866 477 3687 ...

Reviews: