background image

FLIR

 

MR160

 

USER

 

GUIDE

       

     

      

Document

 

Identifier:

 

MR160

en

US_AA

 

27

10. Warranties

10.1

 

FLIR

 

Test

 

&

 

Measurement

 

Imaging

 

Product

 

2

 

year/10

 

year

 

Limited

 

Warranty

 

Congratulations!

 

You

 

(the

 

“Purchaser”)

 

are

 

now

 

the

 

owner

 

of

 

a

 

world

class

 

FLIR

 

Imaging

 

Test

 

and

 

Measurement

 

product.

 

A

 

qualifying

 

FLIR

 

Imaging

 

Test

 

and

 

Measurement

 

product

 

(the

 

“Product”)

 

purchased

 

either

 

directly

 

from

 

FLIR

 

Commercial

 

Systems

 

Inc.

 

and

 

affiliates

 

(FLIR)

 

or

 

from

 

an

 

authorized

 

FLIR

 

distributor

 

that

 

Purchaser

 

registers

 

on

line

 

with

 

FLIR

 

is

 

eligible

 

for

 

coverage

 

under

 

FLIR’s

 

industry

leading

 

2

10

 

Limited

 

Warranty,

 

subject

 

to

 

the

 

terms

 

and

 

conditions

 

in

 

this

 

document.

 

This

 

warranty

 

only

 

applies

 

to

 

purchases

 

of

 

Qualifying

 

Products

 

(see

 

below)

 

purchased

 

after

 

July

 

2014

 

and

 

only

 

to

 

the

 

original

 

Purchaser

 

of

 

the

 

Product.

 

PLEASE

 

READ

 

THIS

 

DOCUMENT

 

CAREFULLY;

 

IT

 

CONTAINS

 

IMPORTANT

 

INFORMATION

 

ABOUT

 

THE

 

PRODUCTS

 

THAT

 

QUALIFY

 

FOR

 

COVERAGE

 

UNDER

 

THE

 

2

10

 

LIMITED

 

WARRANTY,

 

PURCHASER’S

 

OBLIGATIONS,

 

HOW

 

TO

 

ACTIVATE

 

THE

 

WARRANTY,

 

WARRANTY

 

COVERAGE,

 

AND

 

OTHER

 

IMPORTANT

 

TERMS,

 

CONDITIONS,

 

EXCLUSIONS

 

AND

 

DISCLAIMERS.

  

1.

 

PRODUCT

 

REGISTRATION

.

 

To

 

qualify

 

for

 

FLIR’s

 

2

10

 

Limited

 

Warranty,

 

the

 

Purchaser

 

must

 

fully

 

register

 

the

 

Product

 

directly

 

with

 

FLIR

 

on

line

 

at

 

www.flir.com

 

WITHIN

 

Sixty

 

(60)

 

DAYS

 

of

 

the

 

date

 

the

 

Product

 

was

 

purchased

 

by

 

the

 

first

 

retail

 

customer

 

(the

 

“Purchase

 

Date”).

 

PRODUCTS

 

THAT

 

ARE

 

NOT

 

REGISTERED

 

ON

LINE

 

WITHIN

 

Sixty

 

(60)

 

DAYS

 

OF

 

THE

 

PURCHASE

 

DATE

 

OR

 

PRODUCTS

 

WHICH

 

DO

 

NOT

 

QUALIFY

 

FOR

 

THE

 

2

10

 

WARRANTY

 

WILL

 

HAVE

 

A

 

LIMITED

 

ONE

 

YEAR

 

WARRANTY

 

FROM

 

THE

 

DATE

 

OF

 

PURCHASE.

  

2.

 

QUALIFYING

 

PRODUCTS

.

 

Upon

 

registration,

 

a

 

list

 

of

 

thermal

 

Imaging

 

Test

 

and

 

Measurement

 

Products

 

that

qualify

 

for

 

coverage

 

under

 

FLIR’s

 

2

10

 

Warranty

 

can

 

be

 

found

 

at

 

www.flir.com/testwarranty

 

3.

 

WARRANTY

 

PERIODS

.

 

The

 

2

10

 

Limited

 

Warranty

 

has

 

two

 

separate

 

periods

 

of

 

warranty

 

coverage

 

(the

“Warranty

 

Period”),

 

depending

 

on

 

the

 

Imaging

 

Test

 

and

 

Measurement

 

Product

 

part:

  

Product

 

components

 

(excluding

 

thermal

 

imaging

 

sensor)

 

are

 

warranted

 

for

 

a

 

period

 

of

 

two

 

(2)

 

years

 

from

 

the

 

Purchase

 

Date;

  

Thermal

 

imaging

 

sensor

 

is

 

warranted

 

for

 

a

 

period

 

of

 

ten

 

(10)

 

years

 

from

 

the

 

Purchase

 

Date.

  

Any

 

Product

 

that

 

is

 

repaired

 

or

 

replaced

 

under

 

warranty

 

is

 

covered

 

under

 

this

 

2

10

 

Limited

 

Warranty

 

for

 

one

 

hundred

 

eighty

 

days

 

(180)

 

days

 

from

 

the

 

date

 

of

 

return

 

shipment

 

by

 

FLIR

 

or

 

for

 

the

 

remaining

 

duration

 

of

 

the

 

applicable

 

Warranty

 

Period,

 

whichever

 

is

 

longer.

 

4.

 

LIMITED

 

WARRANTY

.

 

In

 

accordance

 

with

 

the

 

terms

 

and

 

conditions

 

of

 

this

 

2

10

 

Limited

 

Warranty,

 

and

 

except

as

 

excluded

 

or

 

disclaimed

 

in

 

this

 

document,

 

FLIR

 

warrants,

 

from

 

the

 

Purchase

 

Date,

 

that

 

all

 

fully

 

registered

 

Products

 

will

 

conform

 

to

 

FLIR’s

 

published

 

Product

 

specifications

 

and

 

be

 

free

 

from

 

defects

 

in

 

materials

 

and

 

workmanship

 

during

 

the

 

applicable

 

Warranty

 

Period.

 

PURCHASER’S

 

SOLE

 

AND

 

EXCLUSIVE

 

REMEDY

 

UNDER

 

THIS

 

WARRANTY,

 

AT

 

FLIR’S

 

SOLE

 

DISCRETION,

 

IS

 

THE

 

REPAIR

 

OR

 

REPLACEMENT

 

OF

 

DEFECTIVE

 

PRODUCTS

 

IN

 

A

 

MANNER,

 

AND

 

BY

 

A

 

SERVICE

 

CENTER,

 

AUTHORIZED

 

BY

 

FLIR.

 

IF

 

THIS

 

REMEDY

 

IS

 

ADJUDICATED

 

TO

 

BE

 

INSUFFICIENT,

 

FLIR

 

SHALL

 

REFUND

 

PURCHASER’S

 

PAID

 

PURCHASE

 

PRICE

 

AND

 

HAVE

 

NO

 

OTHER

 

OBLIGATION

 

OR

 

LIABILITY

 

TO

 

BUYER

 

WHATSOEVER.

  

5.

 

WARRANTY

 

EXCLUSIONS

 

AND

 

DISCLAIMERS

.

 

FLIR

 

MAKES

 

NO

 

OTHER

 

WARRANTY

 

OF

 

ANY

 

KIND

 

WITH

RESPECT

 

TO

 

THE

 

PRODUCTS.

 

ALL

 

OTHER

 

WARRANTIES,

 

EXPRESS

 

OR

 

IMPLIED,

 

INCLUDING

 

BUT

 

NOT

 

LIMITED

 

TO

 

IMPLIED

 

WARRANTIES

 

OF

 

MERCHANTABILITY,

 

FITNESS

 

FOR

 

A

 

PARTICULAR

 

PURPOSE

 

(EVEN

 

IF

 

PURCHASER

 

HAS

 

NOTIFIED

 

FLIR

 

OF

 

ITS

 

INTENDED

 

USE

 

FOR

 

THE

 

PRODUCTS),

 

AND

 

NON

INFRINGEMENT

 

ARE

 

EXPRESSLY

 

EXCLUDED

 

FROM

 

THIS

 

AGREEMENT.

  

THIS

 

WARRANTY

 

EXPRESSLY

 

EXCLUDES

 

ROUTINE

 

PRODUCT

 

MAINTENANCE,

 

AND

 

SOFTWARE

 

UPDATES.

 

FLIR

 

FURTHER

 

EXPRESSLY

 

DISCLAIMS

 

ANY

 

WARRANTY

 

COVERAGE

 

WHERE

 

THE

 

ALLEGED

 

NONCONFORMITY

 

IS

 

DUE

 

TO

 

NORMAL

 

WEAR

 

AND

 

TEAR

 

OTHER

 

THAN

 

SENSORS,

 

ALTERATION,

 

MODIFICATION,

 

REPAIR,

 

ATTEMPTED

 

REPAIR,

 

IMPROPER

 

USE,

 

IMPROPER

 

MAINTENANCE,

 

NEGLECT,

 

ABUSE,

 

IMPROPER

 

STORAGE,

 

FAILURE

 

TO

 

FOLLOW

 

ANY

 

PRODUCT

 

INSTRUCTIONS,

 

DAMAGE

 

(WHETHER

 

CAUSED

 

BY

 

ACCIDENT

 

OR

 

OTHERWISE),

 

OR

 

ANY

 

OTHER

 

IMPROPER

 

CARE

 

OR

 

HANDING

 

OF

 

THE

 

PRODUCTS

 

CAUSED

 

BY

 

ANYONE

 

OTHER

 

THAN

 

FLIR

 

OR

 

FLIR’S

 

EXPRESSLY

 

AUTHORIZED

 

DESIGNEE.

  

THIS

 

DOCUMENT

 

CONTAINS

 

THE

 

ENTIRE

 

WARRANTY

 

AGREEMENT

 

BETWEEN

 

PURCHASER

 

AND

 

FLIR

 

AND

 

SUPERSEDES

 

ALL

 

PRIOR

 

WARRANTY

 

NEGOTIATIONS,

 

AGREEMENTS,

 

PROMISES

 

AND

 

UNDERSTANDINGS

 

BETWEEN

 

PURCHASER

 

AND

 

FLIR.

 

THIS

 

WARRANTY

 

MAY

 

NOT

 

BE

 

ALTERED

 

WITHOUT

 

THE

 

EXPRESS

 

WRITTEN

 

CONSENT

 

OF

 

FLIR.

  

Summary of Contents for MR160

Page 1: ...USER MANUAL FLIR MODEL MR160 IMAGING MOISTURE METER 99 Washington Street Melrose MA 02176 Phone 781 665 1400 Toll Free 1 800 517 8431 Visit us at www TestEquipmentDepot com...

Page 2: ...u Icons Overview 9 5 OPERATION 10 5 1 Powering the Meter 10 5 1 1 Auto Power OFF APO 10 5 2 Moisture Measurements and Display Overview 10 5 2 1 Moisture Measurement Overview 10 5 2 2 Display Overview...

Page 3: ...Waste 19 7 SPECIFICATIONS 20 8 TECHNICAL SUPPORT 21 9 MATERIAL GROUPS 22 9 1 Common Names of Timbers BS888 589 1973 with MR160 Group Nos 22 9 2 Botanical names of timbers with MR160 program group num...

Page 4: ...ein are used for identification only and are the property of their respective owners 1 2 Quality Assurance The Quality Management System under which these products are developed and manufactured has b...

Page 5: ...cautions and notes FLIR Systems reserves the right to discontinue models parts or accessories and other items or to change specifications at any time without prior notice 2 2 Laser Safety Warning Sta...

Page 6: ...proper use will provide years of reliable service 3 1 Key Features FLIR Lepton microbolometer Focal Plane Array FPA with integrated shutter delivers best in class thermal imaging Quickly indicate the...

Page 7: ...ure button 3 Four 4 Navigation buttons rim 4 Select button center 5 Back button 6 Laser Pointer Cross hairs button 7 Power button 8 Ext Probe jack USB port Charging LED 9 Laser pointer lens back 10 Th...

Page 8: ...erface to transfer images to computer or other compatible device Press to back out of return from a menu screen Press to activate laser pointer cross hairs in thermal imaging modes Press to power the...

Page 9: ...mode list Items 9 through 12 are the Moisture mode selection icons Material Group Pin mode Pinless mode and Set Reference mode respectively Press icon 3 to view the Moisture mode icon list A blue dot...

Page 10: ...sensor rear or by connecting an external pin probe NOTE Objects in close proximity to the internal pinless moisture sensor located on the rear of the unit will affect the reading on the display Keep...

Page 11: ...ser pointer ON OFF 8 Moisture reading digital format 9 Moisture reading bargraph format appears blue when in non Alarm state 10 High Moisture Alarm setting see Sections 5 4 and 5 7 11 Set Reference va...

Page 12: ...ensor Note the pinless icon 4 on the upper left of the main display when selected 5 SET REFERENCE MODE SET REFERENCE is used to compare the displayed readings against a stored reference measurement se...

Page 13: ...FERENCE mode is selected a new display line will appear preceded by a delta triangle symbol The digits next to the triangle symbol indicate the reference value the measurement recorded when the SET RE...

Page 14: ...ard the area of interest and view the image on the meter display Hot to cold temperatures for images are represented by this color palette progression white grey black blue white See the color palette...

Page 15: ...Laser button to activate 2 Battery status icon is visible when a program menu is accessed 3 IR Thermal Image 4 Cross hairs Press Laser button to activate 5 Tool tips 6 Image mode icons row IR Thermal...

Page 16: ...to switch the alarm ON OFF Refer to Section 5 7 for Alarm mode details The Alarm can be used in pin or pinless mode of operation Press the Select button to save the value and return to the SETTINGS m...

Page 17: ...e Mode 2 Hold the Capture button until crosshairs appear and laser are visible Fig 5 8a 3 While continuing to hold the Capture button aim the laser at the measurement spot 4 Release the Capture button...

Page 18: ...the Select button to return to the SETTINGS mode and save the value or press the back button to cancel and to return to the normal operating mode 6 When the High Alarm is set ON the main display will...

Page 19: ...port is located on the bottom of the meter under the protective flap next to the EXT Probe jack 3 While the meter is charging a blue LED bottom of meter under protective flap indicates that charging i...

Page 20: ...sampling rate 2 samples per second Internal memory 4GB Power supply 3000mAh 2 x 1500mAh Li ion rechargeable batteries Battery life 10 hours minimum Auto Power OFF Programmable OFF 1 5 or 20 minutes L...

Page 21: ...FLIR MR160 USER GUIDE Document Identifier MR160 en US_AA 21...

Page 22: ...ga 1 Kauri Queensland 8 Pine Nicaraguan Pitch 3 Basswood 6 Keruing 5 Pine Parana 2 Beech European 3 Kuroka 1 Pine Ponderosa 3 Berlina 2 Larch European 3 Pine Radiata 3 Binvang 4 Larch Japanese 3 Pine...

Page 23: ...ey Bark 2 Oak American White 1 Sterculia Brown 1 Elm Rock 4 Oak European 1 Stringybark Messmate 3 Elm White 4 Oak Japanese 1 Stringybark Yellow 3 Empress Tree 8 Oak Tasmanian 3 Sycamore 5 Erimado 5 Oa...

Page 24: ...sungulis 1 Fraxinus excelsior 1 Pipadeniastrum africanum 1 Araucaria angustifolia 2 Fraxinus japonicus 1 Piptadenia africana 1 Araucaria bidwilli 2 Fraxinus mardshurica 1 Podocarpus dacrydiodes 2 Arau...

Page 25: ...ectona grandis 5 Dalbergia latifolia 1 Nothofagus cunninghamii 1 Terminalia superba 1 Diospyros virginiana 6 Ochroma pyramidalis 1 Thuja plicata 3 Dipterocarpus Keruing 5 Ocotea rodiaei 3 Thujopsis do...

Page 26: ...5 15 1 12 5 14 15 3 15 5 13 4 11 8 11 8 15 16 13 5 15 16 3 16 7 14 1 12 5 12 6 15 6 17 14 4 16 16 9 17 5 14 8 13 13 2 16 17 7 14 9 17 17 7 18 8 15 7 14 3 13 9 16 6 18 5 15 3 18 18 2 19 7 16 3 15 14 5...

Page 27: ...a period of ten 10 years from the Purchase Date Any Product that is repaired or replaced under warranty is covered under this 2 10 Limited Warranty for one hundred eighty days 180 days from the date o...

Page 28: ...oduct as a non warranty return FLIR shall not be responsible for any data images or other information that may be stored on the returned Product which was not included in the Product at the time of pu...

Page 29: ...t Identifier MR160 en US_AA 29 Publication Identification No MR160 en US Release Version AA Release Date 2015 February Language en US Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA...

Reviews: