Although a basic understanding of the construction of low-slope commercial roofs is
desirable when carrying out a roof thermography inspection, expert knowledge is not
necessary. There is a large number of different design principles for low-slope com-
mercial roofs—both when it comes to material and design—and it would be impossible
for the infrared inspection person to know them all. If additional information about a
certain roof is needed, the architect or contractor of the building can usually supply
the relevant information.
Common causes of roof failure are outlined in the table below (from SPIE Thermosense
Proceedings Vol. 371 (1982), p. 177).
%
Cause
47.6
Poor workmanship
2.6
Roof traffic
16.7
Poor design
7.8
Trapped moisture
8.0
Materials
8.4
Age & weathering
Potential leak locations include the following:
■
Flashing
■
Drains
■
Penetrations
■
Seams
■
Blisters
7.2.3.2
Safety precautions
■
Recommend a minimum of two people on a roof, preferably three or more.
■
Inspect the underside of the roof for structural integrity prior to walking on it.
■
Avoid stepping on blisters that are common on built up bitumen and gravel roofs.
■
Have a cell phone or radio available in case of emergency.
■
Inform local police and plant security prior to doing nighttime roof survey.
7
20
Publ. No. 1557882 Rev. a156 – ENGLISH (EN) – February 28, 2006
7 – Introduction to building thermography
Summary of Contents for ThermaCAM B2
Page 2: ......
Page 4: ......
Page 6: ......
Page 7: ...ThermaCAM B2 User s manual Publ No 1557882 Rev a156 ENGLISH EN February 28 2006...
Page 191: ......