1.4.10
Auto Push Button
Legend
FUNCTION
Description
Screen Symbology
Reference/Notes
Auto
Control Type:
Momentary push button
Function:
Functionality dependent on selected
sensor as follows;
-
TV
AUTO
GAIN&IRIS
1)
TV sensor selected;
Momentary push sets the TV in Auto
Gain & Iris mode.
Text field 2:
TV/A
TI
AUTO
SPAN&LEVEL
2)
TI sensor selected;
Momentary push sets the TI in Auto
Span & Level mode.
Text field 2:
TI/A
SPOTTER
AUTO
IRIS&GAIN
3)
Spotter sensor selected;
Momentary push sets the Spotter in
Auto Iris mode.
Text field 2:
SP/AI
NUC
SCENE
NUC
4)
TI sensor selected;
A simultaneous momentary push on
the
FUNC
and
Auto
buttons will
initiate a NUC.
This action should only be performed
when the system is in
STOW
position (see § 1.4.14). This is
because the TI-camera must have a
uniform scene to properly perform
the NUC function.
If the
FUNC
and
Auto
buttons are
simultaneous pushed and hold down
for more than two (2) seconds, a
Scene NUC will be initiated.
Text field 6:
NUC
NOTE:
The difference between a NUC and Scene NUC is that a Scene NUC is calculating the
surroundings temperature during the NUC procedure. The Scene NUC will normally take more than 1
minute to perform, while the normal NUC will take 15-20 seconds.