background image

 

 

Safety & Installation Guide  

 

 

Version: 01.12 

 

Valid from 22.10.2018 

 

FG2P1-4S1P00/1 

 

12 

This manual 

applies only on Flisom’s eFlex Series modules 

3.6 

Electrical 

For elevated areas irradiation can be higher than at STC. Therefore, multiply I

SC

- and V

OC

- values with 

a factor of 1.25 for the electrical layout of cables, fuses and converters (worst case scenario). For a 
serial connection the voltage of a single module is multiplied by the number of modules to calculate 
the system voltage. Make sure that you are always within the limits of the maximum system voltage. 

Use an adequate device for overcurrent protection (fuse, blocking diode). Maximum Isc multiplied by a 
factor of 1.56 to protect a string in parallel configuration. 

The maximum number of modules connectable in series is calculated by adding Voc of each single 
module multiplied by 1.25 up to the maximum system voltage which you can find on the label. 

Do not use PV modules of different power classes or configurations in the same PV system. Flisom 
eFlex Series modules use PV4-S connectors. Only use these connectors or compatible connector 
types which are authorised from both producers. Use solar cables for outside use (ø 2.5 to 4mm² and 
min. 90 °C). Check that no cable is under tensile stress or bended over a sharp edge. 

Secure all electrical connections and use stress relief appliances. Do not go below the minimum 
bending radius of the cables. Use cable guides to prevent connectors and cables from lying in excess 
water, snow or dirt. 

The junction box rating is IP65 and IP67 and is not to be opened. The diode cannot be replaced. 

For electrical system installation check all relevant codes, guidelines and regulations. The system 
connection has to be done by a qualified installer. 

3.6.1 

Grounding modules 

Flisom eFlex modules do not require grounding of the modules. For system grounding check all 
relevant codes, guidelines and regulations. 

 

3.6.2 

Inverter 

Inverters convert direct current into alternating current. Inverters of the latest generation, with MPPT 
(Maximum Power Point Tracker), optimize the production, even in situations of weather changes or 
variable sunlight. 

Suitable inverter configurations are: 

 

Central inverters 

 

String inverters 

 

Multi-String inverters 

 

Inverters on single module level 

Not all inverter without transformers can be used. Please contact Flisom for further information.  

 

 

Summary of Contents for eFlex 2x1

Page 1: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 1 This manual applies only on Flisom s eFlex Series modules Flisom eFlex Series Safety Installation Guideline for eFlex...

Page 2: ...4 Technical Information 13 5 Operation 14 6 Inspection and Maintenance 14 7 Disposal 14 8 Disclaimer 14 9 Information 14 9 1 Third Party Supplier Information 15 Warning Flisom eFlex PV Modules are ele...

Page 3: ...electrical fire and other codes and regulations in addition to the specific recommendations stated in this manual The Flisom eFlex Series modules are not intended for self installation by end users T...

Page 4: ...rubbing materials for cleaning the modules Do not use sharps objects Do not walk on the panels if there is any risk that sharp stones under the soles or sharp shoe elements would damage the panel The...

Page 5: ...nds to use personal protective equipment such as safety gloves safety googles and safety boots etc Respect general safety rules 3 1 Environment Ambient temperature to install Flisom eFlex Series modul...

Page 6: ...Flex Series modules receive the same amount of direct sunlight within the same string taking in account their orientation and shadowing If direct shadow on active surface could not be avoided Orientat...

Page 7: ...necessary GAF TPO ask supplier if primer is necessary Stevens TPO ask supplier if primer is necessary Johns Manville TPO ask supplier if primer is necessary Rubber membrane Carlisle EPDM ask supplier...

Page 8: ...instructions If a roof is damaged it has to be replaced before installation of the modules To clean a TPO EPDM or metal roof use IPA 2 propanol isopropyl alcohol and lint free wipes The cleaning shou...

Page 9: ...ex modules Leave enough space between module strings for the cable duct Check that the cable duct is not shading the modules Cover the Junction box with the cable duct system for additional UV protect...

Page 10: ...10 2018 FG2P1 4S1P00 1 10 This manual applies only on Flisom s eFlex Series modules 2 Remove 15cm of the white protective foil on the short side with the junction box 3 Put the module on the marked p...

Page 11: ...the area around the junction box and the junction box on the roof 5 Remove slowly the rest of the white protection foil and press the module simultaneously with a rubber roller on the roof Always rol...

Page 12: ...ompatible connector types which are authorised from both producers Use solar cables for outside use 2 5 to 4mm and min 90 C Check that no cable is under tensile stress or bended over a sharp edge Secu...

Page 13: ...6m eFlex 2 3m eFlex 3 1m Nominal power PMPP W 30 55 85 110 Tolerance of nom power P W 0 5 0 5 0 5 0 5 Voltage at nom power VMPP V 34 35 37 36 Current at nom power IMPP A 0 88 1 54 2 29 3 06 Open circ...

Page 14: ...odules must be disposed of in a responsible manner Please contact your local supplier or disposal company for further information For health and safety reasons Flisom eFlex Series modules should not b...

Page 15: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 15 This manual applies only on Flisom s eFlex Series modules 9 1 Third Party Supplier Information...

Page 16: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 16 This manual applies only on Flisom s eFlex Series modules...

Reviews: