background image

 

 

Safety & Installation Guide  

 

 

Version: 01.12 

 

Valid from 22.10.2018 

 

FG2P1-4S1P00/1 

 

14 

This manual 

applies only on Flisom’s eFlex Series modules 

Operation 

According to local regulations it might be necessary to contact authorities before the PV system is 
connected to the grid. Also check if this has to be performed by authorized personnel. 

Inspection and Maintenance 

It is recommended to have a visual check on a regular basis (quarterly). Plan check-ups according to 
the given environmental and safety conditions and regulations. 

 

Remove dust and dirt (sediments, leaves, pollen, bird droppings, etc.) from the surface.  

 

Do not use aggressive cleaning agents or scrubbing materials for cleaning 

 

Do not use steam blasting for cleaning. 

 

Use soft water to avoid chalk stains 

 

Soft Sponges can be used 

 

Check if connectors and grounding are tight and without corrosion and if the insulation is not 
damaged also check for loose mechanical or electrical contacts.  

 

Check if the Junction Box is securely attached and that no deep scratches are penetrating the 
frontsheet 

Disposal 

Flisom eFlex series modules must be disposed of in a responsible manner. Please contact your local 
supplier or disposal company for further information. For health and safety reasons, Flisom eFlex 
Series modules should not be disposed of with household garbage, and must be dealt with in 
accordance with local codes and regulations.  

Disclaimer 

Flisom eFlex series modules can change in appearance and electrical parameters because of the 
improvements of components or changes of suppliers or minor design modifications. These changes 
are typically made without customer notification. Modules with the same classification have the same 
functionality and are fully compatible with one another. 

Since Flisom has no control of the correct use of the safety and installation guideline, Flisom is not 
responsible for injuries, operational errors, damages and expenses caused by incorrect handling, 
installation, operation or maintenance. 

Flisom is not responsible for licence or patent infringements or other rights of third parties caused by 
the usage of the eFlex Series modules. There is no implicit guarantee of licences, patents implicated. 

Information 

Company Address  

 

Flisom AG 

Gewerbestrasse 16 

8166 Niederhasli 

Switzerland 

 

Tel:  

+41 (0)44 824 30 00 

Fax:  

+41 (0)44 824 30 01 

Web:  

www.flisom.com 

Email:  

info@flisom.ch

 

 

Summary of Contents for eFlex 2x1

Page 1: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 1 This manual applies only on Flisom s eFlex Series modules Flisom eFlex Series Safety Installation Guideline for eFlex...

Page 2: ...4 Technical Information 13 5 Operation 14 6 Inspection and Maintenance 14 7 Disposal 14 8 Disclaimer 14 9 Information 14 9 1 Third Party Supplier Information 15 Warning Flisom eFlex PV Modules are ele...

Page 3: ...electrical fire and other codes and regulations in addition to the specific recommendations stated in this manual The Flisom eFlex Series modules are not intended for self installation by end users T...

Page 4: ...rubbing materials for cleaning the modules Do not use sharps objects Do not walk on the panels if there is any risk that sharp stones under the soles or sharp shoe elements would damage the panel The...

Page 5: ...nds to use personal protective equipment such as safety gloves safety googles and safety boots etc Respect general safety rules 3 1 Environment Ambient temperature to install Flisom eFlex Series modul...

Page 6: ...Flex Series modules receive the same amount of direct sunlight within the same string taking in account their orientation and shadowing If direct shadow on active surface could not be avoided Orientat...

Page 7: ...necessary GAF TPO ask supplier if primer is necessary Stevens TPO ask supplier if primer is necessary Johns Manville TPO ask supplier if primer is necessary Rubber membrane Carlisle EPDM ask supplier...

Page 8: ...instructions If a roof is damaged it has to be replaced before installation of the modules To clean a TPO EPDM or metal roof use IPA 2 propanol isopropyl alcohol and lint free wipes The cleaning shou...

Page 9: ...ex modules Leave enough space between module strings for the cable duct Check that the cable duct is not shading the modules Cover the Junction box with the cable duct system for additional UV protect...

Page 10: ...10 2018 FG2P1 4S1P00 1 10 This manual applies only on Flisom s eFlex Series modules 2 Remove 15cm of the white protective foil on the short side with the junction box 3 Put the module on the marked p...

Page 11: ...the area around the junction box and the junction box on the roof 5 Remove slowly the rest of the white protection foil and press the module simultaneously with a rubber roller on the roof Always rol...

Page 12: ...ompatible connector types which are authorised from both producers Use solar cables for outside use 2 5 to 4mm and min 90 C Check that no cable is under tensile stress or bended over a sharp edge Secu...

Page 13: ...6m eFlex 2 3m eFlex 3 1m Nominal power PMPP W 30 55 85 110 Tolerance of nom power P W 0 5 0 5 0 5 0 5 Voltage at nom power VMPP V 34 35 37 36 Current at nom power IMPP A 0 88 1 54 2 29 3 06 Open circ...

Page 14: ...odules must be disposed of in a responsible manner Please contact your local supplier or disposal company for further information For health and safety reasons Flisom eFlex Series modules should not b...

Page 15: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 15 This manual applies only on Flisom s eFlex Series modules 9 1 Third Party Supplier Information...

Page 16: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 16 This manual applies only on Flisom s eFlex Series modules...

Reviews: