Safety & Installation Guide
Version: 01.12
Valid from 22.10.2018
FG2P1-4S1P00/1
5
This manual
applies only on Flisom’s eFlex Series modules
2
Storage and Transportation
The eFlex modules with applied PV600BT adhesive should be stored in a shaded, dry and clean area
between 15°C - 25°C.
When stored correctly the adhesive is usable up to 12 months. (see datasheet
HELIOBOND® PVA 600 BT in section 9.1)
Do not stand or step on the modules or their packaging. Do not accept modules delivered in damaged
packaging. Do not put pressure on the modules. Do not bend the modules to a radius of less than
500mm.
2.1
Packaging
The eFlex modules are packed in cardboard boxes. Box must not be stacked more than 3 Boxes high
eFlex 2x1
eFlex 3x1
eFlex 4x1
Dimension (LxWxH)
80x40x47cm
80x40x47cm
80x40x47cm
Quantity of modules
4
4
4
Weight of a full box
modules without glue
10.4 kg
15.2 kg
19.2 kg
Weight of a full box
modules with glue
7.2 kg
10.8 kg
14,0 kg
Note: Other sizes to be confirmed.
3
Installation
Before installing modules, contact the appropriate authorities to obtain any required building permits
and to determine installation and inspection requirements that apply to the installation. Make sure that
unauthorised people have no access to the construction place. Do not install when it is raining,
snowing, windy or the ground is slippery. Flisom recommends to use personal protective equipment
such as safety gloves, safety googles and safety boots etc. Respect general safety rules.
3.1
Environment
Ambient temperature to install Flisom eFlex Series modules must be between 10°C and 50°C. They
can be operated in the range of -40°C to 85°C. Check if it is necessary to protect animals from the PV
system for example by installing cable guides or fences etc. Depending on the area it is necessary to
protect the modules from standing water, snow or extreme soiling. The described application solution
is limited to a snow and wind load (wind suction) of 2400 N/m
2
. At consistent solar radiation Flisom PV
modules generate more power at lower temperatures. To improve the energy yield of the plant
increasing cooling or ventilation is an option (see thermal coefficients in the data sheet).
3.2
Handling
Flisom eFlex Series use thin polymeric sheets as backsheet. Hence they can bend by applying forces
while installation (e.g. dropping on the edges or corner). Please handle with care. Store modules in a
dry place. Do not transport modules without packaging. Do not put modules on top of each other to
avoid small scratches (this can accelerate module degradation by environmental factors). Do not use
Junction Box cables as handles to carry or lift the modules. Be cautious when frontsheet is wet since
the surface will be slippery. Do not apply solvents, adhesives, paint or stickers on the frontsheet. Do
not place the modules face-down in direct contact to abrasive surfaces. Do not bend a module over a
sharp edge.