Storage and Transportation 

The eFlex modules with applied PV600BT adhesive should be stored in a shaded, dry and clean area 
between 15°C - 25°C.

 

When stored correctly the adhesive is usable up to 12 months. (see datasheet 

HELIOBOND® PVA 600 BT in section 9.1)

 

Do not stand or step on the modules or their packaging. Do not accept modules delivered in damaged 
packaging. Do not put pressure on the modules. Do not bend the modules to a radius of less than 
500mm. 

2.1 

Packaging 

The eFlex modules are packed in cardboard boxes. Box must not be stacked more than 3 Boxes high

  

 

 

eFlex 2x1 

eFlex 3x1 

eFlex 4x1 

Dimension (LxWxH) 

80x40x47cm 

80x40x47cm 

80x40x47cm 

Quantity of modules 

Weight of a full box 

modules without glue 

10.4 kg 

15.2 kg 

19.2 kg 

Weight of a full box 

modules with glue 

7.2 kg 

10.8 kg 

14,0 kg 

  

Note: Other sizes to be confirmed. 

Installation 

Before installing modules, contact the appropriate authorities to obtain any required building permits 
and to determine installation and inspection requirements that apply to the installation. Make sure that 
unauthorised people have no access to the construction place. Do not install when it is raining, 
snowing, windy or the ground is slippery. Flisom recommends to use personal protective equipment 
such as safety gloves, safety googles and safety boots etc. Respect general safety rules. 

3.1 

Environment 

Ambient temperature to install Flisom eFlex Series modules must be between 10°C and 50°C. They 
can be operated in the range of -40°C to 85°C. Check if it is necessary to protect animals from the PV 
system for example by installing cable guides or fences etc. Depending on the area it is necessary to 
protect the modules from standing water, snow or extreme soiling. The described application solution 
is limited to a snow and wind load (wind suction) of 2400 N/m

2

. At consistent solar radiation Flisom PV 

modules generate more power at lower temperatures. To improve the energy yield of the plant 
increasing cooling or ventilation is an option (see thermal coefficients in the data sheet).  

3.2 

Handling 

Flisom eFlex Series use thin polymeric sheets as backsheet. Hence they can bend by applying forces 
while installation (e.g. dropping on the edges or corner). Please handle with care. Store modules in a 
dry place. Do not transport modules without packaging. Do not put modules on top of each other to 
avoid small scratches (this can accelerate module degradation by environmental factors). Do not use 
Junction Box cables as handles to carry or lift the modules. Be cautious when frontsheet is wet since 
the surface will be slippery. Do not apply solvents, adhesives, paint or stickers on the frontsheet. Do 
not place the modules face-down in direct contact to abrasive surfaces. Do not bend a module over a 
sharp edge. 

Summary of Contents for eFlex 2x1

Page 1: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 1 This manual applies only on Flisom s eFlex Series modules Flisom eFlex Series Safety Installation Guideline for eFlex...

Page 2: ...4 Technical Information 13 5 Operation 14 6 Inspection and Maintenance 14 7 Disposal 14 8 Disclaimer 14 9 Information 14 9 1 Third Party Supplier Information 15 Warning Flisom eFlex PV Modules are ele...

Page 3: ...electrical fire and other codes and regulations in addition to the specific recommendations stated in this manual The Flisom eFlex Series modules are not intended for self installation by end users T...

Page 4: ...rubbing materials for cleaning the modules Do not use sharps objects Do not walk on the panels if there is any risk that sharp stones under the soles or sharp shoe elements would damage the panel The...

Page 5: ...nds to use personal protective equipment such as safety gloves safety googles and safety boots etc Respect general safety rules 3 1 Environment Ambient temperature to install Flisom eFlex Series modul...

Page 6: ...Flex Series modules receive the same amount of direct sunlight within the same string taking in account their orientation and shadowing If direct shadow on active surface could not be avoided Orientat...

Page 7: ...necessary GAF TPO ask supplier if primer is necessary Stevens TPO ask supplier if primer is necessary Johns Manville TPO ask supplier if primer is necessary Rubber membrane Carlisle EPDM ask supplier...

Page 8: ...instructions If a roof is damaged it has to be replaced before installation of the modules To clean a TPO EPDM or metal roof use IPA 2 propanol isopropyl alcohol and lint free wipes The cleaning shou...

Page 9: ...ex modules Leave enough space between module strings for the cable duct Check that the cable duct is not shading the modules Cover the Junction box with the cable duct system for additional UV protect...

Page 10: ...10 2018 FG2P1 4S1P00 1 10 This manual applies only on Flisom s eFlex Series modules 2 Remove 15cm of the white protective foil on the short side with the junction box 3 Put the module on the marked p...

Page 11: ...the area around the junction box and the junction box on the roof 5 Remove slowly the rest of the white protection foil and press the module simultaneously with a rubber roller on the roof Always rol...

Page 12: ...ompatible connector types which are authorised from both producers Use solar cables for outside use 2 5 to 4mm and min 90 C Check that no cable is under tensile stress or bended over a sharp edge Secu...

Page 13: ...6m eFlex 2 3m eFlex 3 1m Nominal power PMPP W 30 55 85 110 Tolerance of nom power P W 0 5 0 5 0 5 0 5 Voltage at nom power VMPP V 34 35 37 36 Current at nom power IMPP A 0 88 1 54 2 29 3 06 Open circ...

Page 14: ...odules must be disposed of in a responsible manner Please contact your local supplier or disposal company for further information For health and safety reasons Flisom eFlex Series modules should not b...

Page 15: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 15 This manual applies only on Flisom s eFlex Series modules 9 1 Third Party Supplier Information...

Page 16: ...Safety Installation Guide Version 01 12 Valid from 22 10 2018 FG2P1 4S1P00 1 16 This manual applies only on Flisom s eFlex Series modules...