DESCRIPTION

The model LM51DN electronic lube meter is designed 

specifically to dispense motor oils (SAE 5…50), gear oils 

(SAE 80…240), automatic transmission fluid, antifreeze 

(Ethylene Glycol), brake fluid, windshield wiper fluid, 

and engine coolant solutions. Modular design, low cost, 

lightweight and rugged make the LM51DN the best choice 

for overhead reel systems.
The electronic register module contains a microprocessor 

board powered by a lithium battery. It can be programmed 

to dispense in pints, quarts, liters, or US gallons and 

will totalize in liters or US gallons. The meter calibration 

factor is determined during factory test. The meter can 

be recalibrated in the field for fluids or different viscosity 

if required. A 6-digit liquid crystal display, accurate to the 

second decimal place, shows the exact amount of fluid 

dispensed. The entire register module is protected from 

the wear and tear of normal shop use by a rugged, glass 

filled, shock resistant, nylon housing.

OPERATION

As fluid passes through the metering chamber by entering 

the inlet port, the internal gears rotate, forcing the fluid 

to exit through the outlet port. Each rotation of the gear 

displaces a given volume of fluid.
The display shows the amount of fluid dispensed since the 

last time the reset button was pushed. Pushing the reset 

button will reset the display to zero for the next dispense.

To Change the Unit of Measure

1.  Press 

TOTAL

 three times followed by 

RESET

 three times 

in a time frame of under 2 seconds. The active unit of 

measure symbol will flash when you have entered pro-

gramming mode.

2.  Press 

RESET

 until desired unit of measure flashes on 

the display.

3.  To exit the programming mode, press and hold 

RESET 

and 

TOTAL

 simultaneously for 3 seconds.

NOTE

: Changing any unit of measure will reset the non-

resettable and resettable totalizers.

920841-02

10/14

To Program the Scale Factor

1.  Press 

TOTAL

 three times followed by 

RESET

 three times 

in a time frame of under 2 seconds. The active unit of 

measure symbol will flash when you have entered pro-

gramming mode.

2.  Press 

TOTAL

 to advance to the first digit of the scale factor.

3.  The selected digit will blink. Push 

RESET

 to change the 

value.

4.  When the proper value displays, push 

TOTAL

 to move 

to the next digit.

5.  Continue until the correction factor has been entered.
6.  To exit the programming mode, press and hold 

RESET

 

and 

TOTAL

 simultaneously for 3 seconds.

The display will flash three times and then go blank to indicate 

the changes have been saved.