background image

Table of Contents

3

Thank you for purchasing a top quality, factory tested pump.

Page

General Safety .....................................................................................................2

Warranty ..............................................................................................................3

Installation ...........................................................................................................4

Electrical ...........................................................................................................5,6

Troubleshooting ...................................................................................................7

Repair Parts .........................................................................................................7

ATTACH ORIGINAL RECEIPT HERE FOR WARRANTY CONSIDERATION.

FLOTEC warrants to the original consumer purchaser (“Purchaser”) of its prod-
ucts that they are free from defects in material or workmanship.
If within twelve (12) months from the date of the original consumer purchase
any such product shall prove to be defective, it shall be repaired or replaced at
FLOTEC’s option, subject to the terms and conditions set forth below. Your orig-
inal receipt of purchase is required to determine warranty eligibility.

Exceptions to the Twelve (12) Month Warranty
Ninety (90) Day Warranty:

If within ninety (90) days from original consumer purchase any Drill Pump,
Pitcher Pump, or In-Line Water Filter Cartridge shall prove to be defective, it
shall be replaced, subject to the terms set forth below.

Two (2) Year Warranty:

If within two (2) years from original consumer purchase any 1/3 HP Submersible
Sump Pump or Model FP2800DCC shall prove to be defective, it shall be
repaired or replaced at FLOTEC’s option, subject to the terms and conditions set
forth below.

Three (3) Year Warranty:

If within three (3) years from original consumer purchase any 4” Submersible
Well Pump, or 1/2 HP Submersible Sump Pump, shall prove to be defective, it
shall be repaired or replaced at FLOTEC’s option, subject to the terms and con-
ditions set forth below.

Four (4) Year Warranty:

If within four (4) years from original consumer purchase any FLOODMATE

TM

7000 or IRONMATE

TM

Submersible Sump Pump shall prove to be defective, it

shall be repaired or replaced at FLOTEC’s option, subject to the terms and con-
ditions set forth below.

Five (5) Year Warranty:

If within five (5) years from original consumer purchase any Pre-Charge water
system tank shall prove to be defective, it shall be repaired or replaced at
FLOTEC’s option, subject to the terms and conditions set forth below.

General Terms and Conditions

Purchaser must pay all labor and shipping charges necessary to replace product
covered by this warranty. This warranty shall not apply to acts of God, nor shall
it apply to products which, in the sole judgement of FLOTEC, have been sub-
ject to negligence, abuse, accident, misapplication, tampering, alteration; nor
due to improper installation, operation, maintenance or storage; nor to other
than normal application, use or service, including but not limited to, opera-
tional failures caused by corrosion, rust or other foreign materials in the system,
or operation at pressures in excess of recommended maximums.
Requests for service under this warranty shall be made by returning the defec-
tive product to the Retail outlet or to FLOTEC as soon as possible after the dis-
covery of any alleged defect. FLOTEC will subsequently take corrective action
as promptly as reasonably possible. No requests for service under this warran-
ty will be accepted if received more than 30 days after the term of the warran-
ty.
This warranty sets forth FLOTEC’s sole obligation and purchaser’s exclusive
remedy for defective products.
FLOTEC SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL,
OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL
OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND
FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE
DURATION OF THE APPLICABLE EXPRESS WARRANTIES PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or conse-
quential damages or limitations on how long an implied warranty lasts, so the
above limitations or exclusions may not apply to you. This warranty gives you
specific legal rights and you may also have other rights which vary from state
to state.

Flotec Limited Warranty

FLOTEC • P.O. Box 342 • Delavan, WI U.S.A. 53115

Phone: 1-800-365-6832 • Fax: 1-800-526-3757

E-Mail: info@flotecwater.com • Web Site: http://www.flotecwater.com

Summary of Contents for FP5500 Series

Page 1: ...nt Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 8 13 Instalaci n Operaci n Piezas Para mayor informaci n sobre el...

Page 2: ...a qualified electrician GENERAL SAFETY Do not touch an operating motor Modern motors are designed to operate at high temperatures To avoid burns when servicing pump allow it to cool for 20 minutes aft...

Page 3: ...red or replaced at FLOTEC s option subject to the terms and conditions set forth below General Terms and Conditions Purchaser must pay all labor and shipping charges necessary to replace product cover...

Page 4: ...prime following instructions above When used with vertical discharge the vent plug at the top should be loosened to evacuate air which is trapped inside the volute When volute is completely filled wit...

Page 5: ...r 1 2 wrench and turn the volt age selector dial counterclockwise until 115 shows in the dial opening 4 Reinstall the motor cover Hazardous voltage Can shock burn or cause death Disconnect power to mo...

Page 6: ...ls L1 and L2 under motor canopy When replacing motor check wiring diagram on motor nameplate against Figure 3 If the motor wiring diagram does not match either diagram in Figure 3 follow the diagram o...

Page 7: ...9 10 10 10 11 13 12 683 0294 FL Key Part FP5512 08 FP5522 08 FP5532 08 FP5542 08 FP5552 08 No Description Qty 1 2 HP 3 4 HP 1 HP 1 1 2 HP 2 HP 1 Motor 115 230V 60 Cycle Single Phase 1 A100CLL A100DLL...

Page 8: ...ratures lev es Pour ne pas se br ler lorsque l on interviendra sur la pompe la laisser refroidir pendant 20 minutes apr s l avoir arr t e avant de la toucher Ne pas laisser geler la pompe ni aucun au...

Page 9: ...ermes et condi tions stipul s ci dessous Conditions g n rales L Acheteur s engage payer tous les frais de main d uvre et d exp dition n cessaires au remplacement du produit couvert par la garantie Cet...

Page 10: ...l le bouchon d a ration qui se trouve en haut doit tre desserr de fa on chasser l air emprisonn dans la volute Lorsque la volute est compl tement remplie d eau resserrer le bouchon d a ration NE JAMAI...

Page 11: ...on vers la gauche jusqu ce que la valeur 115 soit affich e dans l ouverture du cadran 4 Reposer de nouveau le couvercle du moteur Tension dangereuse Risque de secousses lectriques de br lures voire de...

Page 12: ...nsporteurs de courant sur les bornes L1 et L2 qui se trouvent sous le carter du moteur Lorsque l on remplace le moteur comparer le sch ma de c blage de la plaque signal tique par rapport la Figure 3 S...

Page 13: ...rt e et mal ancr e toute contrainte sur la pompe 1 2 3 4 5 6 8 7 9 10 10 10 11 13 12 683 0294 FL N de D signation FP5512 00 FP5522 00 FP5532 00 FP5542 00 FP5552 00 r f des pi ces Qt 1 2 CV 3 4 CV 1 CV...

Page 14: ...ados para operar a temperaturas altas Para evitar quemaduras al realizar el servicio a una bomba d jela enfriar por 20 minutos despu s de apagarla No permita que la bomba o cualquier componente del s...

Page 15: ...consumidor original ste ser reparado o reemplazado a opci n de FLOTEC sujeto a los t rminos y a las condiciones indicadas a continuaci n T rminos y Condiciones Generales El comprador debe pagar todos...

Page 16: ...o las instrucciones anteriores Cuando la descarga sea vertical debe aflojarse el tap n de ventilaci n situado en la parte superior para evacuar el aire que est atrapado dentro de la voluta Cuando la v...

Page 17: ...e tensi n hacia la izquierda hasta que se vea 115 en la abertura del cuadrante 4 Vuelva a instalar la cubierta del motor Tensi n peligrosa Puede causar choques quemaduras o muerte Desconecte la corrie...

Page 18: ...os Paso 7 Conecte los conductores que llevan la corriente a los bornes L1 y L2 bajo el techo del motor Cuando cam bie el motor inspeccione el diagrama de cableado en la placa de f brica del motor cont...

Page 19: ...l anclada aliviar los esfuerzos en el conjunto de la bomba 1 2 3 4 5 6 8 7 9 10 10 10 11 13 12 683 0294 FL No de Descripci n FP5512 00 FP5522 00 FP5532 00 FP5542 00 FP5552 00 Ref de las Piezas Cant 1...

Page 20: ...20...

Reviews: