Installation 4

For parts or assistance, call Flotec Customer Service at 

800-365-6832

Performance

Installation

1.  This unit can be installed in sump pit with 

minimum diameter of 12” (30cm) and depth of 

12” (30cm). Sump pit may be constructed of tile, 

concrete, steel or plastic. Check local codes for 

approved materials.

2.  Install pump on solid, level foundation, as near as 

possible to center of sump pit. Do not hang pump 

from discharge pipe or power cord.

NOTICE Pump must be level (column must be vertical) 

when operating. If motor is tilted, internal start/run 

switch may overheat and damage motor.
3.  Pump should not be installed on clay, earth or sand 

surfaces. Clean sump pit of small stones and gravel 

which could clog the pump. Keep pump inlet 

screen clear.

4.  Thread discharge pipe into pump body carefully to 

avoid stripping or crossing threads.

NOTICE Do not use ordinary pipe joint compound on 

plastic pipe or pump. Pipe joint compound can attack 

plastics and damage pump.
5.  To reduce motor noise and vibrations, a short 

length of rubber hose (1-5/8” (41mm) I.D., e.g. 

radiator hose) can be connected into discharge line 

near pump using suitable clamps. 

 Risk of electric shock. Can shock, burn 

or kill. Pump is designed for 115V., 60 HZ operation 

and requires an individual branch circuit of 15 amperes 

capacity. It is supplied with a 3-wire cord set with 

grounding-type plug for use in a 3-wire, grounded 

outlet. Do not cut off the round grounding prong. For 

safety, outlet must always be electrically grounded to 

a suitable electrical ground such as a grounded water 

pipe or a properly grounded metallic raceway or 

ground wire system.
6.  Locate Float Rod Guide (Key No. 6) about 6” 

(16cm) below motor. Clamp guide to column with 

screw provided. 

 Risk of flooding. Be sure that guide is 

securely clamped so that float rod is vertical and can 

move up and down freely. If float is angled or binds, 

pump may not start, allowing flooding to occur.
7.  Screw float onto threaded end of rod. Threads on 

rod will cut threads into corrosion resistant float.

8.  Insert plain end of float rod up through eye of 

rod guide.

9.  Slide one rod stop on float rod before passing rod 

through eye of pump switch. Slide 2nd rod stop on 

rod after passing through eye of switch. Position 

2nd rod stop flush with top of rod.

10. Position lower rod stop to within 8”(20cm) of 

switch lever arm. With lower rod stop in this 

position, pump will automatically cycle at 

approximately 2-1/2” (6cm) off and 10-12” (25-

30cm) on. For faster cycling, move lower rod stop 

closer to switch lever arm.

11. If pump discharge line is exposed to outside 

subfreezing atmosphere, then portion of line 

exposed must be installed so any water remaining 

in pipe will drain to outfall by gravity. Failure to do 

this can cause water trapped in discharge to freeze 

which could result in damage to pump.

12. Install an in-line check valve (Flotec No. FP0026-

6D) to prevent flow backwards through pump after 

pump shuts off.

NOTICE Flotec check valve FP0026-6D is equipped 

with an air bleed hole to prevent airlocking the pump. 

If using a check valve without an air bleed hole, drill a 

1/8” (3.2mm) hole in discharge pipe just above pump 

body but below the check valve to prevent air locks.
13. After all piping and controls have been installed, 

unit is ready for operation.

14. Run pump through one cycle to check float 

switch operation. 

 Risk of sudden starts. Can cause 

electrical shock and personal injury. The pump motor 

is equipped with automatic resetting thermal protector 

and may restart unexpectedly. Protector tripping is an 

indication of motor overloading as a result of operating 

pump at low heads (low discharge restriction), 

excessively high or low voltage, inadequate wiring, 

incorrect motor connections, or a defective motor.

 5098 0705

Discharge

About 6"

About 8"

Check 
Valve
(Purchase
Separately)

GPH (LPH) at total feet (M)

5 ft (1.52)

10 ft (3.05) 15ft (4.57) 20 ft (6.09)

3000 (11 

355L)

2460 (9 

312L)

1620 (6 

131L)

0 (0L)

Summary of Contents for FPPM3600D

Page 1: ...lation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 365 6832 Fran ais Pages 7 11 Instalaci n Operaci n Piezas Para mayor i...

Page 2: ...e and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt...

Page 3: ...required Risk of fire Do not store or rest objects on or near motor or switch linkage Keep all flammable objects or liquids away from motor 8 Provide means of pressure relief for pumps whose discharg...

Page 4: ...angled or binds pump may not start allowing flooding to occur 7 Screw float onto threaded end of rod Threads on rod will cut threads into corrosion resistant float 8 Insert plain end of float rod up t...

Page 5: ...d minimum check size of wiring from main source If OK contact Electric Comapny or local Hydro authority Faulty automatic switch Operate switch manually and replace if inoperative Float or float rod st...

Page 6: ...Switch FP0020 Switch FP0018 7D Ref Part Description Qty FPPSS3000 FPPM3600D 1 Motor 1 2 Switch 1 3 Volute Pump Body 1 S1 31B PS1 25P 4 Impeller 1 PS5 269P PS5 269P 5 Base Plate 1 PS4 17P PS4 17P 6 Scr...

Page 7: ...la pompe d eaux d gout Porter des gants en caoutchouc pour manipuler la pompe des fins de garantie retourner l tiquette figurant sur le cordon de la pompe et l original du re u au d taillant Mettre la...

Page 8: ...Danger d incendie Ne pas placer d objets sur ou c t du moteur ou du raccord de l interrupteur Tenir le moteur l cart de tout objet ou liquide inflammable 8 Pr voir un moyen de r dui re la pres sion su...

Page 9: ...la tige Le filetage de la tige taraudera un trou dans le flotteur r sistant la corrosion 8 Ins rer l extr mit sans filetage de la tige du flotteur dans l illet du guide de tige 9 Glisser un dispositi...

Page 10: ...es locaux Interrupteur automatique d fectueux Faire fonctionner l interrupteur manuellement et le remplacer si n cessaire Flotteur ou tige de flotteur bioqu e V rifier si le flotteur frotte contre la...

Page 11: ...terrupteur FP0020 Interrupteur FP0018 7D R f D signation des pi ces Qte FPPSS3000 FPPM3600D 1 Moteur 1 2 Interrupteur 1 3 Volute Corps de la pompe 1 S1 31B PS1 25P 4 Impulseur 1 PS5 269P PS5 269P 5 Pl...

Page 12: ...C Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminaci n Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Par...

Page 13: ...alice el mantenimiento peri dico que sea necesario Peligro de Incendio No guarde ni coloque objetos sobre o cerca del motor o interruptor de enlace Mantenga todo objeto o l quido inflamable lejos del...

Page 14: ...nado o se dobla la bomba puede no arrancar y provocar inundaciones 7 Enrosque el flotador al extremo con rosca de la varilla La rosca de la varilla cortar la rosca en el flotador anticorrosivo 8 Inser...

Page 15: ...la autoridad de recursos hidrol gicos Interruptor autom tico defectuoso Accione el interruptor manualmente y reempl celo si no funciona Flotador o varilla del flotador atascados Aseg rese de que el fl...

Page 16: ...or FP0018 7D Ref Part Description Qty FPPSS3000 09 FPPM3600D 09 1 Motor 1 2 Interruptor 1 3 Voluta Cuerpo de la bomba 1 S1 31B PS1 25P 4 Impulsor 1 PS5 269P PS5 269P 5 Placa de base 1 PS4 17P PS4 17P...

Reviews: