Instruction Manual 10159 

Thermo-Optic Sensors and Thermistor Dummy 

PRODUCT DESCRIPTIONS: 

These instructions cover the following FloTech products: 
FT150 

Replacement Thermo-Optic Overfill Probe 

FT151 

Thermo-Optic Sensor with 2”NPT Probe Holder 

FT155 

Electronic 5 Channel Dummy 

FT152 

2 Wire Thermo-Optic Retain Sensor with ½” NPT Probe Holder 

FloTech Thermo-Optic sensor and Thermistor Dummy are mechanically and functionally 
compatible with Civacon Thermistor, Thermo-Optic and Thermistor Dummy components.  
These “Electronic” Thermistor sensors will provide reliable operation when installed as 
replacements to conventional “Green Tipped” Thermistor sensors.  FloTech Thermo-Optic 
sensors and electronic dummy provide high reliability, long life, and quick start up in cold 
weather. “Civacon” is a registered trademarks of Civacon / Dover Corporation. 

INSTALLATION INSTRUCTIONS: 

FloTech model FT151 can be mounted in a 2”NPT female pipe coupling or through a 2 3/8” 
hole.  When mounting in a 2 3/8” hole the gasket and lock nut provided are used to retain the 
probe holder in the tank shell or manhole.  After the sensor is mounted remove the cap. 

Loosen the probe clamp screw and adjust the probe to the correct level point.  This is typically 
3% of compartment volume.  It is not recommended cutting the standard 7” sensor to a shorter 
length.  This will cause insufficient time to stop the flow of product within the load racks 
reaction time.  

IMPORTANT: The actual sensing point adjustment should be determined by the total 
response time required to prevent a tank overfill condition.  The FloTech sensor reaction time 
is one half second.  The loading rack will also have a reaction time.  Once the probe is adjusted 
to the proper height, tighten the clamp screw.

 

Summary of Contents for FT150

Page 1: ...reliability long life and quick start up in cold weather Civacon is a registered trademarks of Civacon Dover Corporation INSTALLATION INSTRUCTIONS FloTech model FT151 can be mounted in a 2 NPT female...

Page 2: ...th leaving approximately 8 inches extra length exiting the top of each probe holder All sensor wires must enter or leave the probe holder through one of the NPT openings Use FloTech FT402 NPT cable gl...

Page 3: ...Dixon Bayco 4740T Interstate Dr Cincinnati OH 45246 Rev May 2017 PH 513 874 8499 FX 513 874 8399 Page 3 Diagram F1...

Page 4: ...ling requires a 1 1 8 inch diameter hole cut in the bottom of the tank After the welded coupling has cooled install the sensor using pipe sealant or Teflon tape to lubricate and seal the threads NOTE...

Page 5: ...rins avec boitier pour sonde de NPT E U Dixon Bayco USA Chestertown Maryland T l phone 410 778 2000 Fax 410 778 4702 Sans frais 800 355 1991 E mail dixonbayco dixonvalve com www dixonbayco com Canada...

Page 6: ...pteur retirez le couvercle Desserrez la vis de serrage de la sonde et ajustez la sonde au niveau appropri Nous ne recommandons pas de couper la sonde de 7 plus courte Cela pourrait nuire aux rampes de...

Page 7: ...l sur la partie sup rieur du support de la sonde Tous les brins du capteur doivent entrer ou sortir du support de la sonde par une des ouvertures de NPT Utilisez le FT402 FloTech de NPT presse toupe p...

Page 8: ...10159 fr Rev May 2017 Diagramme F1...

Page 9: ...ourni un coupleur de soudure de NPT avec chaque capteur Le coupleur exige qu un trou avec un diam tre de 1 1 8 soit coup sur le dessous de la citerne Apr s que l accouplement soud soit refroidi instal...

Reviews: