FloTech FT555 Automatic Truck Overfill System Tester
Page 18
10784PA REV F
FT555 Truck Tester
Trailer ID Module Test
The Trailer ID Module will be tested and report the 12 digit serial
number stored inside the ID module. If there is no trailer ID
module or the test fails the screen will show “TIM not found”
Step 1)
Move the J-Slot thumb screws to the correct holes to match
the type of socket to be connected. Follow the “O” and “T”
markings on the plug body.
Step 2)
Connect the FT555 Automatic Truck Tester to the trailer
socket.
Step 3)
Press the ON/OFF button to turn on the FT555 Automatic
Truck Tester. When “Press Key” screen appears press “TEST
SELECT” button five times so the “Trailer ID Module Test”
screen appears.
Step 4)
Press the “GO” button to start the test. When the test is
complete the screen will report the 12 digit serial number or show
“TIM not found”.
Step 5)
Press the TEST SELECT” button to move on to a new test,
press “GO” to restart the test, or press the “ON/OFF” button to
turn the tester off.
FloTech FT555 Automatic Truck Overfill System Tester
FT555 Truck Tester
10784PA REV F
Page 7
Welcome Screen
After completing the Initial System Setup the welcome screen will
be displayed. This screen will be displayed every time the FT555
Automatic Truck Tester is turned on.
The Welcome Screen shows the version software the FT555 is
running and the battery health status in bars. 5 bars represent full
battery capacity. If 2 or less bars are displayed, a warning beep will
sound and a warning message will flash for a few seconds.
Batteries should be changed at your next convenience.
Power On/Off
Press the ON/OFF button once to turn the tester on. Push the
button again to turn the tester off. The tester has a display back
light for dark conditions. After turning on the tester, press and
hold the ON/OFF button for 2 seconds and the back light will turn
on. Press and hold again for 2 seconds and the back light will turn
off.