FM USER INSTRUCTIONS ENGLISH 71576526 - 03/07
Page 12 of 32
flowserve.com
Maximum working pressure at discharge
.................................................25 bar (363 psi)
Maximum working pressure at suction
.................................................16 bar (232 psi)
Maximum pumped fluid temperature
(1)
105 °C (221 °F): Impeller and diffuser Cast iron
or Bronze
Minimum pumped fluid temperature
.................................................-10 °C (14 °F)
Maximum ambient temperature
.................................................40 °C (104 °F)
Maximum solid suspension
.................................... 50 g/m
3
(0.003 lbm/ft
3
)
Density ............................... 1
Viscosity............................. 1 mm
2
/s (31 SSU)
Frequency ............................................. 50 Hz
Maximum rotation speed ....................... 2850
min
-1
(1)
If mechanical seal: maximum temperature 80 °C
(176 °F)
The maximum speed is shown on the
pump nameplate.
3.2 Nomenclature
Characteristics shown on the nameplate fixed on the pump are as shown below:
Each pump is supplied with the following nameplate:
Each pump unit is supplied with the following nameplate:
Mass of the set
Pump type
Speed of rotation
Flow rate
Year of constr
Manufacture number
Head
Radial/thrust bearing
Mass
Maximum admissible
Pressure at 20 °C (68 °F)
Maximum / minimum
temperature