IJ PUMP OPERATION AND MAINTENANCE MANUAL
BO2660-01 6-18
should you require additional information about a condition or repair which is not covered here,
contact your nearest Flowserve Service Department (see PART ORDERING AND SERVICING
INFORMATION) .
6.5.1 CLEANING
WARNING
Petroleum solvents, alcohol, acetone and other such
chemicals are injurious to health and may ignite from a
spark; make certain that they are used only in a well
ventilated place, away from heat, flame, and sparks.
You should clean the case and all metal parts with acetone, alcohol, a steam cleaner that uses
demineralized water and approved chemicals, or a petroleum solvent such as naphtha or kerosene;
ensure that the cleaning agent used is compatible with the pumped liquid.
Bearing housing components should be cleaned with a solvent such as naphtha or kerosene and dried
with instrument air. To remove gasket sealant from bearing housings, carefully peel old film from
parting surfaces. Use a plastic knife, or equivalent material that is softer than carbon steel. Clean
parting surfaces with denatured alcohol or acetone.
6.5.2 INSPECTION AND REPAIR
6.5.2.1 General
1. Verify that all parts are free of gouges, burrs, scratches, excessive wear, and any other
imperfections. Replace worn or damaged parts.
2. Ensure that all parts are free from dirt, deposits, or old gasket material. Perfectly clean and
smooth surfaces are required. Any part from which deposits cannot be removed must be
replaced.
3. All replacement parts must be obtained from the original equipment manufacturer to ensure
proper tolerances and fit. It is unlikely that a field shop can machine the contour of a part to
the close tolerance which is required to assure that the part, and in turn the assembly, will
meet its design function.
6.5.2.2 Main Lube Oil Pump
To perform any maintenance on the lube oil pump, see its manufacturer's instructions in the
APPENDIX.
6.5.2.3 Bearings
The shoes, base ring halves, and journal halves must be replaced in sets.
6.5.2.4 Mechanical Seal
6.5.2.4.1 Disassembling Seal Unit
After the seal unit has been removed from the pump, disassemble it in accordance with the seal
manufacturer's installation and assembly drawing in the APPENDIX.
Summary of Contents for IJ
Page 2: ...IJ PUMP INSTALLATION OPERATION MAINTENANCE ...
Page 3: ......
Page 5: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 iv ...
Page 11: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 x ...
Page 13: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xii ...
Page 17: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xvi ...
Page 25: ......
Page 35: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 2 10 Figure 2 1 Foundation Bolt ...
Page 65: ......
Page 79: ......
Page 83: ......