IJ PUMP OPERATION AND MAINTENANCE MANUAL
BO2660-01 6-38
6.6.6 MAIN LUBE OIL PUMP INSTALLATION
These instructions provide for installation of a lubricating oil (lube oil) pump that is flange-mounted
to the outboard bearing housing end cover for direct and axial coupling of its shaft with the pump
shaft. If your pump is not equipped with such a lube oil pump, please disregard this section.
6.6.6.1 Installing Half-Couplings
To install half-couplings, proceed as follows:
1. Verify that vibration sensor disk (282) is installed, if applicable (see ASSEMBLY drawing),
also verify that end cover (61) is not installed (see BEARINGS).
2. Install half-coupling key in shaft of vibration sensor disk (282) or in end of pump shaft,
whichever is applicable (see ASSEMBLY drawing), slide half-coupling completely onto key,
and fix half-coupling to shaft of disk or end of pump shaft, whichever is applicable, with
setscrew.
3. Install spider in half-coupling on shaft of vibration sensor disk (282) or end of pump shaft,
whichever is applicable (see ASSEMBLY drawing).
4. Install half-coupling key in shaft of lube oil pump, slide half-coupling onto key, allowing
coupling face to extend past end of lube oil pump shaft. Do not install setscrew.
5. Solidly butt together flanges of lube oil pump and end cover (61); then withdraw lube oil
pump. Measure 0.06 inch (1.5 millimeters) from hub of half-coupling toward lube oil pump
case and mark distance on shaft; then move half-coupling hub to mark and secure it to shaft
with setscrew. There shall be a total gap of 0.06 inch (1.5 millimeters) between spider and
half-couplings.
6. Remove end cover. Apply an even film of sealant to parting surface of end cover that abuts
bearing housing. Install cover with stationary oil baffle or Inproseal stator (if installed), and
evenly tighten capscrews.
7. Wipe off any excess sealant.
6.6.6.2 Installing Lube Oil Pump
To install the lube oil pump, proceed as follows:
1. Ensure:
a. that lube oil pump has been inspected and assembled for operation as given by
manufacturer's instructions in APPENDIX;
b. that half-couplings are free of burrs and gouges;
c. that half-couplings are installed and held firmly in place by setscrews (see INSTALLING
HALF-COUPLING above).
2. Install spider in half-coupling on shaft of vibration sensor disk (282) or end of pump shaft,
whichever is applicable (see ASSEMBLY drawing).
3. Keep half-coupling on lube oil pump shaft aligned with spider so that half-coupling on lube
oil pump shaft will mesh with spider and flanges of lube oil pump and end cover (61) will
butt together solidly. Run capscrews through holes in lube oil pump and evenly and tightly
screw capscrews into end cover (61), securing lube oil pump to cover.
Summary of Contents for IJ
Page 2: ...IJ PUMP INSTALLATION OPERATION MAINTENANCE ...
Page 3: ......
Page 5: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 iv ...
Page 11: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 x ...
Page 13: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xii ...
Page 17: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xvi ...
Page 25: ......
Page 35: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 2 10 Figure 2 1 Foundation Bolt ...
Page 65: ......
Page 79: ......
Page 83: ......