IJ PUMP OPERATION AND MAINTENANCE MANUAL
BO2660-01 2-2
CAUTION
Parts can be damaged by using the end of the pump shaft as
lifting points.
Avoid lifting the pump by nozzles or drip pockets, they are
not stressed for the load.
NOTE
Whenever practicable, rig or fabricate an apparatus of
chains, cables, hooks, clevises, and devices such as spreader
bars that would prevent cables from cutting into pump,
driver, piping, panels, lagging, etc., thus avoiding any need
to remove equipment to avoid damage.
Should it become necessary to lift the complete pump or the
case off the soleplates and there are no lifting holes in the
pump feet, it should be lifted by a single nylon lifting strap
placed around the case at the center of gravity.
2.1.3.1 Baseplate-Mounted Pump and Driver
The four cardinal points for lifting the combined weight of baseplate and mounted pump and driver
(or just the baseplate with pump) are located towards the ends of the baseplate. Their positions are
physically defined by pipes that act as holders for lifting bars or lugs that afford use of clevises. These
pipes or lugs are welded to the baseplate structure (see the OUTLINE drawing in the back of this
manual). To set up for lifting the baseplate, proceed according to the following outline.
1. Slide 3 in (75 mm) bars which are long enough to extend well past sides of baseplate into
pipes in baseplate or attach clevises to lifting lugs at each end of baseplate, whichever is
applicable.
2. Attach cables to 3 in (75 mm) bars or clevises in lugs at the four cardinal points.
3. Attach hoist to apparatus, take up slack in cables and check to see that cables do not cut into
pump, driver, or attached equipment. If it appears that cable will cut into an item, stop hoist,
and protect item with wood blocks, if possible; otherwise remove the item.
4. Insure that hoist is over center of gravity of baseplate and that cables are not cutting into any
item.
5. Hoist unit and dispose of it.
NOTE
After the baseplate has been secured in position, verify that
pump and equipment are undamaged and that items which
had been removed for lifting the baseplate have been
reinstalled (see INSTALLING NOZZLE EXTENSIONS AND
GROUTING).
Summary of Contents for IJ
Page 2: ...IJ PUMP INSTALLATION OPERATION MAINTENANCE ...
Page 3: ......
Page 5: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 iv ...
Page 11: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 x ...
Page 13: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xii ...
Page 17: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xvi ...
Page 25: ......
Page 35: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 2 10 Figure 2 1 Foundation Bolt ...
Page 65: ......
Page 79: ......
Page 83: ......