IJ PUMP OPERATION AND MAINTENANCE MANUAL
3-13
BO2660-01
NOTE
All indicator readings must be taken on the periphery or rim
of the coupling hub or shaft, and recorded as viewed from
the fixed unit (see ALIGNMENT ORIENTATION figure).
FIXED UNIT
3
12
3
6
9
1
2
4
3
12
3
6
9
1
2
4
MOVABLE UNIT
Figure 3-12 Alignment Orientation
f. Attach bracket to the movable unit coupling hub or shaft. (see DIAL INDICATOR
SETUP FOR ALIGNMENT figure) Take the readings on the fixed unit coupling hub or
shaft.
g. Set the bar sag amount determined in steps a through e above into the indicator as a plus
amount (example: an indicated -0.003 would be set in as a +0.003) while in the upright
(12 o'clock) position.
h. Rotate both shafts 180° (to the 6 o'clock position) and record indicator reading.
i. Repeat steps g and h to verify accuracy.
j. Set the bracket to the horizontal (9 o'clock) position and set indicator to "0". Bar sag is
not applicable in the horizontal position.
k. Rotate both shafts 180° (to the 3 o'clock position) and record indicator reading.
l. Repeat steps j and k to verify accuracy.
Summary of Contents for IJ
Page 2: ...IJ PUMP INSTALLATION OPERATION MAINTENANCE ...
Page 3: ......
Page 5: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 iv ...
Page 11: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 x ...
Page 13: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xii ...
Page 17: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xvi ...
Page 25: ......
Page 35: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 2 10 Figure 2 1 Foundation Bolt ...
Page 65: ......
Page 79: ......
Page 83: ......