IJ PUMP OPERATION AND MAINTENANCE MANUAL
BO2660-01 6-16
b. Remove the intermediate cover (33) or destaging spacer (292) (if installed) using the
procedure outlined in INTERFERENCE FIT PART REMOVAL above.
9. Remove the suction impeller (28) as follows:
a. Set up soft-faced V-blocks near base assembly. The blocks should be positioned to
support the shaft at points about 25% of total shaft length from the ends of the shaft. The
block under the coupling end must not prevent removal of the suction impeller (28) from
the free end of the shaft.
b. Install shaft hoisting fitting on free end of shaft. Attach soft cable and hoist to fitting and
move shaft to V-blocks. Place nylon lifting strap and hoist on coupling side of suction
impeller (28) and use both hoists to place shaft in V-blocks.
NOTE
To remove the suction impeller, it may be necessary to strike
the impeller skirt with two soft-faced mallets at points 180
degrees apart using simultaneous blows.
c. Heat and remove suction impeller (28) using the procedure outlined in INTERFERENCE
FIT PART REMOVAL above. Remove split ring (545) (if installed) and impeller key(s)
(25 or 112).
11. If required, set the shaft aside by placing nylon lifting straps under each end about 25% of
total shaft length away from the ends and lifting the shaft out of the V-blocks using one hoist
on each strap or one hoist and a spreader bar. The shaft must be stored on a flat, solid surface,
at least 6 inches (150 mm) above a metal or concrete surface. The suction spacer (23) may be
set aside by installing lifting gear, if required, and moving it from the base assembly to any
convenient area.
6.4.6.2.4 Horizontal Disassembly
To disassemble the internal assembly in the horizontal position, proceed as follows:
1. Set up U-shaped channel for disassembly of internal assembly.
2. Place nylon lifting strap under intermediate cover (33) at each end of the internal assembly so
that the load is evenly distributed. Then use one hoist on each strap or one hoist and a
spreader bar to lift the internal assembly and place it in the U-shaped channel. Turn the
internal assembly so that the assembly rail (462) is on top, then remove lifting gear and
assembly rail (462).
NOTE
See the ASSEMBLY drawing in the back of this manual, to
determine the method used to secure the pressure reducing
sleeve (77).
3. Remove pressure reducing sleeve locknut (86 or 678) or split ring retainer (277) and split ring
(614), as applicable.
4. Heat and remove pressure reducing sleeve (77) using the procedure outlined in
INTERFERENCE FIT PART REMOVAL above. If necessary, slide the drum toward the
coupling end of shaft to clear and remove split ring (614) before removing sleeve. Remove
the pressure reducing sleeve key (88).
Summary of Contents for IJ
Page 2: ...IJ PUMP INSTALLATION OPERATION MAINTENANCE ...
Page 3: ......
Page 5: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 iv ...
Page 11: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 x ...
Page 13: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xii ...
Page 17: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 xvi ...
Page 25: ......
Page 35: ...IJ PUMP OPERATION AND MAINTENANCE MANUAL BO2660 01 2 10 Figure 2 1 Foundation Bolt ...
Page 65: ......
Page 79: ......
Page 83: ......