flowserve.com
5. Place new
vent piece
to secure t
6. Place spoo
7. Place
the
s
on the ram
(figures 12
8.6 Stem
The position fe
information to t
of a rotary pos
through a feed
of the pin in the
side of the slot
automatically m
in the unlikely e
Stem Positio
To replace the
and 25 and pr
are required:
Phillips
sc
WARNING
electrostat
Figure 18: Ste
w molded filter e
e. This filter ele
the O-ring insta
ol valve shroud
spool valve cove
mp and sliding it
and 17) and se
m Position S
eedback assem
the processor.
ition sensor tha
dback linkage. T
e slot, the follow
t with a rotary sp
moves the posit
event of failure
n Sensor Rep
e stem position
roceed as outlin
crewdriver
G:
Observe pre
tically sensitive
em Position Se
element into the
ement provides
alled in the last
d onto spool va
er assembly in p
until the tab sea
ecure with a 8-3
Sensor
bly transmits va
This is accomp
at connects to th
To provide for a
wer arm is biase
pring. This sprin
tion feedback as
of any compone
placement
n sensor, refer t
ned below. Th
ecautions for ha
e devices.
nsor Orientatio
Use
e chamber cov
s part of the tra
t step.
alve cover.
place by setting
ats in the slot
32 screw.
alve positions
plished by mean
he valve stem
accurate tracking
ed against one
ng also
ssembly to its lim
ent in the linkag
to figure 15, 18
he following too
andling
on
er instructions
ver
ck
g it
ns
g
mit
ge.
8
ols
1. Mak
2. Disc
3. Rem
4. Rem
reta
5. Disc
PCB
6. Rem
and
7. Turn
side
the
8. Inse
poin
pos
the
prot
NOT
olde
with
320
pos
– Digital Positi
ke sure the valv
connect the po
move the main
move the plasti
aining screws.
connect the po
B assembly.
move the two ro
d lift the sensor
n the new posi
e of the shaft is
position senso
ert the position
nting toward th
ition sensor clo
housing screw
trude over the
TE:
Do not mix
er Logix positio
h different rang
00MD model. T
ition sensor ar
ioner 3200MD
ve is bypassed
ower and air su
cover.
ic board cover
(See Figure 15
osition sensor w
otary position s
r out of the hou
tion sensor sha
s aligned with th
or. (Figure 18.)
sensor into the
e main PCB as
ockwise until b
w holes and the
main PCB ass
x the position s
oners. Older m
es that will not
The wires on th
re red, white an
LGENIM0059
d or in a safe co
pply to the unit
by removing th
5.)
wires from the m
sensor-retainin
sing.
aft until the dot
he wires on the
)
e shaft with the
ssembly. Turn
olting slots alig
e wires on the s
embly.
sensor with thos
models contain s
t work in the Lo
he Logix 3200M
nd black.
9-04 09/11
25
ondition.
t.
he three
main
ng screws
t on the
e side of
e wires
the
gn with
sensor
se from
sensors
ogix
MD