47
Flowserve US Inc.
SIHI
dry
dry
dry
dry
Standard
Standard
Standard
Standard M Series
Dry Running Vacuum Pump
Issue Date: November 21, 2016 Copyright:
FLOWSERVE SIHI Pumps Rev 1
Control of SIHIdry Pump:
The SIHIdry
has four operation sequence options:
Start/Stop by power on and off: [Default Setting by wire jumpers] The SIHIdry is running as a simple
pump at a fixed operating full speed. When the voltage is switched on and the Purge control device
signals a safe operation (main power supply and 24V ON by the Operating Company) the pump runs
up automatically. In case of trouble the pump stops automatically and comes to a standstill.
Standard AC-D1: [Default Setting] the behavior of the SIHIdry
is determined by the application board
connected with a superior control system (Plant DCS) making available digital and analogue control
signals. It can also be connected to a local control panel (optional).
Optional Control (SIHI Control [SABO]): The behavior of the SIHI
dry
is determined by a superior
control system making available digital and analogue control signals. The theoretical value can be set
or fixed programmed by means of the optional control panel, analogue interface or by digital interface.
Wireless connection: is on board the SIHIdry, with the SIHIapp on ANDROID all monitoring actions
and by safe settings also the control of the SIHIdry can be done on Smartphone or tablet.
Note: The SIHIdry
Vacuum Pump is equipped with either the STE12 [12 kW] Electronic Board or
the STE30 [30 kW] Electronic Board - Please see separated Vacuum Pump or System BOM-List
and compare material # with below list to determine which Electronic Board is installed:
7.3.3.1
Sterling Electronic STE12 – Board
Material # of STE 12 - Synchronization Board: see 11 Spare Part List
[Default Synchronization Board for M100 to M400]
Figure 17: STE 12 - Synchronization Board