Dry Running Vacuum Pump
Issue Date: November 21, 2016 Copyright:
FLOWSERVE SIHI Pumps Rev 1
10.4.6 Cooling Water
Functionality of the flow meter and the flow rate must be checked at regular intervals. Likewise, the
level in the cooling jacket of the SIHIdry
system must be checked regularly: For this purpose, remove
the bleeder screw in the casing cover (cover plate) of the vacuum pump. The level
should be approximately 0.5 – 0.75 inch [1.5 to 2 cm] below the upper edge of the casing to allow
expansion of the coolant when heated. A foot ruler can be used for checking the level. The required
quantity of the coolant must be filled as per the specifications in the data sheet (see "supplementary
data sheets"). Close the casing jacket with the bleeder screw subsequently.
10.5 Disassembly / Assembly
In this chapter the disassembly of the SIHIdry, the exchange of the screw spindle pair and the assembly
of the SIHIdry are described. Proceed in the indicated order and observe the safety measures as
described in chapter 4 as well as the weight information in the following sections.
Caution! Handling of heavy parts
Therefore:
In order to change the complete
SIHI
dry
pump, the
lifting gear and transport slings must be designed for
a minimum load capacity of 1,455lbs [620 kg]
In order to change single parts, the lifting gear and
transporting slings must be designed for the following
minimum load capacities:
-
Housing cover 15.32lbs [6.950 kg]
-
Casing 109.3lbs [49.6 kg]
-
Pump head with housing 363.76lbs [165 kg ]
-
Electronic housing 181.21lbs [82.2 kg]