12.2 Fault, Error & Trouble Shooting
No.
Text
Cause
Rectifying measure
through
5
DRY – Sync.Reg
System error
DRY: Sync.Reg - internal error
ERROR_FLASH_DATATYPES
Repeat the start-up. Then inform the Service.
Service
6
DRY – Sync.Reg
System error
DRY: Sync.Reg - internal error
ERROR_FLASH_W RITE
Repeat the start-up. Then inform the Service.
Service
8
DRY – Sync.Reg
System error
DRY: Sync.Reg - internal error
ERROR_FLASH_PARASET:MISMAT
Repeat the start-up. Then inform the Service.
Service
9
DRY – Sync.Reg
System error
DRY: Sync.Reg - internal error
ERROR_UNEXPECTED_MACHINE
Repeat the start-up. Then inform the Service.
Service
121
DRY - Error in the free
rotation at rotor diagnostics
Pump DRY: Rotor diagnostics are
stopped due to the fault, if so
Repeat the start-up. If necessary, clean the pump. Then
inform the
Operator
122
DRY - Rotation angle too
small
Pump DRY: Rotor diagnostics are
stopped due to the fault, if so
Repeat the start-up. If necessary, clean the pump. Then
inform the
Operator
134
Boot mode activated
Drives are in the Boot mode
Reset boot switch
Operator
135
DRY – Emergency stop:
Mains phase failure
Pump: Mains phase failure
Check power supply
Operator
140
DRY: Pump rotates in the
re- verse direction due to
Incorrect direction of rotation of the
motors due to external influences
Check the operating behavior of the system
Operator
201
DRY - Emergency stop: De-
viation control is too high
Pump DRY: The difference in angles
between the pump displacer is too
Clean Pump.
Remove foreign bodies.
Operator
202
DRY - Emergency stop:
Drive difference torques is
Pump DRY: The difference in drive
torques in the pump displacer is too
Clean the pump. Remove the foreign bodies.
Operator
203
Angular deviation rate limit
too high
Angular deviation rate limit too high
Clean the pump. Remove foreign bodies
Operator
204
Angular deviation limit
Angular deviation limit exceeded
permanently
Clean the pump. Remove foreign bodies
Operator
235
DRY - Emergency stop: Net
phase loss
Pump DRY: Net phase loss activates
the con- trolled shut down.
Service
250
DRY - Emergency stop:
Connection to pump
Pump DRY: Pump or device stops as
communication is lost to the Sterling
Control the Bus connection wiring (STERLING link PtP)
between the main STERLING control module and the
Service
271
Excess temperature of left
motor
Temperature monitoring
Check the operating behavior of the system
Operator