Flowserve US Inc.
SIHI
dry
dry
dry
dry
Standard
Standard
Standard
Standard M Series
Dry Running Vacuum Pump
Issue Date: November 21, 2016
Copyright:
FLOWSERVE SIHI Pumps
80
1510 Final position control:
The cooling medium FSL is not
closed
The NAMUR cooling medium sensor FSL
does not register a closed final position.
W ith a turned on coolant pump and with
avail- able cooling medium, the sensor
must register the final position as closed.
- Cooling medium pump was not turned on.
- No cooling medium available.
- Control cooling medium loop.
Operator
1511 Final position control:
The cooling medium FSL is not
open
The NAMUR cooling medium sensor FSL
does not register an open final position.
W ith a turned off coolant pump, the
sensor must register the final position
- Cooling medium pump will not turn off.
- Control sensor settings.
Operator
1512 Final position control: N2-
flushing is not closed
No start ENABLE or emergency stop
The valve is not actuated and the closed
NAMUR sensor in no final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1513 Final position control: N2-
flushing is not open
No start ENABLE or emergency stop
The valve is actuated and the open
NAMUR
Control the end switch and the valve. Control
the compressed air supply
Operator
1514 Final position control:
The condenser outlet is not
open
No start ENABLE or emergency stop
The valve is actuated and the open
NAMUR
Control the end switch and the valve. Control
the compressed air supply
Operator
1515 Final position control:
The condenser outlet is not
closed
No start ENABLE or emergency stop
The valve is not actuated and the closed
NAMUR sensor in no final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1516 Final position control:
The condenser drain is not
open
No start ENABLE or emergency stop
The valve is actuated and the open
NAMUR
Control the end switch and the valve. Control
the compressed air supply
Operator
1517 Final position control:
The condenser drain is not
closed
No start ENABLE or emergency stop
The valve is not actuated and the closed
NAMUR sensor in no final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1518 Final position control:
The condenser valve is not
open
No start ENABLE or emergency stop
The valve is actuated and the open
NAMUR
Control the end switch and the valve. Control
the compressed air supply
Operator