1519 Final position control:
The condenser valve is not
closed
No start ENABLE or emergency stop
The valve is not actuated and the closed
NAMUR sensor in no final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1520 Final position control:
The condenser outlet is not
open
No start ENABLE or emergency stop
Condenser suction side:
The condenser outlet sensor does not
register an open final position.
Control the end switch and the valve. Control
the compressed air supply
Operator
1521 Final position control:
The condenser outlet is not
closed
No start ENABLE or emergency stop
Condenser suction side:
The condenser outlet sensor does not
register a closed final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1522 Final position control:
The condenser drain is not
open
No start ENABLE or emergency stop
Condenser suction side:
The condenser drain sensor does not
register an open final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1523 Final position control:
The condenser drain is not
closed
No start ENABLE or emergency stop
Condenser suction side:
The condenser drain sensor does not
register a closed final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1524 Final position control:
The condenser valve is not
open
No start ENABLE or emergency stop
Condenser suction side:
The condenser sensor does not
register an open final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1525 Final position control:
The condenser valve is not
closed
No start ENABLE or emergency stop
Condenser suction side:
The condenser sensor does not
register a closed final position
Control the end switch and the valve. Control
the compressed air supply
Operator
1526 Final position control:
The cooling water valve is not
open
No start ENABLE or emergency stop
Cooling water valve:
The valve is actuated and the open
NAMUR
Control the end switch and the valve. Control
the compressed air supply
Operator
1527 Final position control:
The cooling water valve is not
closed
No start ENABLE or emergency stop
Cooling water valve:
The booster valve is not actuated
and the closed NAMUR sensor in no
Control the end switch and the valve. Control
the compressed air supply
Operator