SVCN 7 INSTALLATION, OPERATION, & MAINTENANCE
Bent Wire
Oiling Rings
(2889A)
Oiling Ring
Retainer (356)
Figure 4-2 Oil Ring Positioning for Shaft Removal
19. Remove the oiling rings (2889A), then loosen the oiling ring retainer screws and remove the
oiling ring retainer (356).
4.4 INSPECTION AND RENEWAL OF PARTS
After the pump has been disassembled for repair or overhaul, each part should be cleaned and
inspected. Any parts deemed unacceptable for further use should be replaced with new parts, unless
otherwise instructed. Detailed instructions are given in the following paragraphs.
4.4.1 CLEANING
WARNING
Fumes from alcohol, acetone, petroleum solvents and
other such chemicals are injurious to health and may
ignite from a spark. Ensure that the area where they are
used is well ventilated and has a fire extinguisher nearby.
When the pump is used in a steam or water circuit, all internal parts of the pump should be cleaned
with a non-petroleum-based cleaning agent such as alcohol or acetone or a steam cleaner that uses
steam from demineralized water. Petroleum-based agents such as dry cleaning solvent or kerosene
may be used for cleaning when the cleaning agent will dissolve in the pumped liquid without ill
effect. Petroleum-based agents should be used to clean the bearing housing and associated parts.
4.4.2 INSPECTION OF PARTS
The following parts must be inspected for conditions that can impair pump operation before
reassembling the pump. Unusable parts should be replaced rather than repaired, except as noted
below. Some items are cross-referenced to a detailed procedure.
- 4-5 -
DO2604-13
Summary of Contents for SVCN 7
Page 2: ...SVCN 7 PUMP INSTALLATION OPERATION MAINTENANCE 1 ...
Page 15: ......
Page 57: ......
Page 60: ...SVCN 7 INSTALLATION OPERATION MAINTENANCE 5 3 DO2604 13 ...