instruction in the “Reset Factory Default Settings” Section in the “Hardware Set-
up” Chapter of this manual.
I am unable to get any video from all the cameras
Is the Ethernet cable used to connect the cameras or the video server to the
Videomesh a crossover cable?
A standard Ethernet cable does not work to connect an IP camera or a video
server to a Videomesh. Make sure that you are using an appropriate
crossover
Ethernet cable rather than a standard Ethernet cable.
Is the local network properly set-up to forward every packet for the class 5.0.0.0,
1.0.0.0 and 2.0.0.0 to the main gateway(s)?
The LAN that connects the
mesh gateway
to the recording server (NVR or DVR)
need to be configured in such a way that every packet for the class 5.0.0.0,
1.0.0.0, and 2.0.0.0 is forwarded to the Videomesh that act as
gateway
for the
entire mesh network.
I am unable to get any video from some cameras
Is the Ethernet cable used to connect the cameras or the video server to the
Videomesh a cross-over cable?
A standard Ethernet cable does not work to connect an IP camera or a video
server to a Videomesh. Make sure that you are using an appropriate
cross-over
Ethernet cable rather than a standard Ethernet cable.
Is the Videomesh IP address where the cameras are attached present in the
routing table of the gateway?
In case the Videomesh IP address is not present in the routing table of the
gateway, the Videomesh might be powered-off or out of range.
26