Inst464
–
Viron e-Quilibirum Series Chlorinator Instructions V07-20
16
5.4 Installation of the pH sensor
The optional pH sensor eliminates the need to regularly test your pH balance of your pool and spa.
The sensor will require
checking and recalibrating approximately once every 6 months.
When installed and connected the Viron e-Quilibrium will automatically detect the pH sensor and the factory pH setpoint is
7.6
. You can adjust your ideal pH setting in the “settings” menu.
The pH sensor is supplied with a sensor chamber that is connected into 50mm PVC pipe work using 50mm union tails and
lock nuts. Locate the sensor chamber (diagram below) in a vertical, where possible after the filter but before chlorinators
Cell. Glue in 50mm PVC pipe into union tails. Alternatively, locate the sensor chamber in a vertical position after the filter
and before the chlorinator cell. Remove rubber boot from pH sensor and screw into the sensor chamber port as shown.
The remaining ports in the sensor chamber are blanked off using the caps and gaskets supplied as per the assembly
diagram below.