6.8 Acid Pump squeeze tube
:
Acid pump squeeze tube must be lubricated every 6 months or more often in commercial applications. Use only the
recommended lubricant RC Tube Lube available from AstralPool or any other compatible silicone lubricant, otherwise
damage to the tube is possible.
Depending upon usage, the squeeze tube may need replacement after 12months on a domestic installation, and earlier on a
commercial installation. Before replacing the tube make sure that any stop valves in the filter system are closed. Otherwise
water loss may occur.
(To replace the tube, remove controller drawer, remove retaining screws from the pump head and pull the tube free.
Disconnect the squeeze tube from the barbs and reconnect the new squeeze tube after lubricating the same, making sure
that the new tube is correctly connected to the PVC tubing as per instructions. Reposition the squeeze tube in the unit as
before, replace the pump head and retaining screws.) DO NOT OVERTIGHTEN THE RETAINING SCREWS.
6.9 Sensors
:
The sensors are sensitive instruments. To maintain their accuracy they should be cleaned periodically by household
detergent abrasive like Jif. Jif is the preferred option. The Chlorine Sensor tip can be contaminated (generally observed by a
copper or brownish coating
–
this should always look shiny gold) which will give a false reading to the Controller causing no
dosing/over dosing of chlorine. As the pH sensor tip is made of glass, please take care, for even a hairline crack can cause
the sensor to read incorrectly causing malfunction.
After cleaning the sensors, wash with water, allow 5-10min. to settle and check calibration or re-calibrate if necessary.
Note, the chlorine sensor may take 30 to 45 minutes to settle and provide the correct reading.
7.0 Ai Mode
– complete automatic control of your Pool & Spa
Ai Mode is a unique Patent Applied for system that controls the filtration and chlorine levels in your pool with three primary
objectives:
Completely turnover your pool water every day so that the organic material which looks unsightly and which feeds algae
and bacteria is removed from your pool.
Ensures the correct sanitizer level is achieved to destroy any pathogens, algae and bacteria in the water.
Minimizes the cost of operating your pool and spa.
7.1 Ai Equipment requirements
For your Viron e-Quilibrium to operate in Ai Mode you will need the following equipment:
A Viron e-Quilibrium
pH sensor
chlorine sensor
RJ12 communications cable
Viron eVo variable speed pump
7.2 Ai Mode Connection
Connect your Viron eVo pump to the Viron e-Quilibrium with the RJ12 communications cable and plug the 3 pin plug into
the bottom.
7.3 Ai Mode set up
In the Viron e-Quilibri
um “Set Up” screen enter “INSTALL” menu and enable
the following:
3 speed pump enabled the volume of your pool and spa in litres (if no spa is installed, leave this at factory pre-set level)
select Ai Mode
Select the size Viron Pump you have installed (1.0 hp for P320/XT320 and 2.0 hp for P600/XT520)
Select the speed of the pump when you have the system manually on
–
we recommend speed 1 or high speed.
Select “Continue” set up when asked.
the number of complete water turnovers required each day, (suggest factory preset of 1.5 times is adequate)
When asked “Reset to Factory Defaults?” select no.
Finally, exit the “Install Menu” and c
hange the timer period to operate for as long as possible (suggestion of 16 hours
–
from
8 am to 10 pm)