8
It is important to note that there are factors that affect how you select the right size
of CUV for your pool.
Your CUV will keep your pool clear of green water up to its maximum capacity as
stated above along with an appropriate sanitiser.
The CUV range is an effective unit and has multiple uses. It can be used on large
pools, aquaculture and other installations, please contact your local dealer for
further details.
FLOW RATES
Please note:
For optimum performance we recommend that you pass the entire
volume of your pool through the CUV unit
at least
once every 4 to 8 hours.
The slower the flow the higher the dosage of UV.
We do not recommend the use of pumps with operating pressures in excess of
2.5 bar / 25 metres of head.
Model
Pool size
Max. flow rate
Bulb power
Inlet / Outlet
CUV15V3
15m
3
7,500 Litres/hr
15W (1 X 15W T8)
1½"
CUV25V3
25m
3
10,000 Litres/hr
25W (1 X 25W T8)
1½"
CUV30V3
30m
3
15,000 Litres/hr
30W (1 X 30W T8)
1½"
CUV55V3
55m
3
20,000 Litres/hr
55W (1 X 55W T8)
1½"
CUV75V3
75m
3
25,000 Litres/hr
75W (1 X 75W T8)
1½"
CUV110N
110m
3
25,000 Litres/hr
110W (2 X 55W T8)
2"
CUV220N
180m
3
25,000 Litres/hr
220W (4 X 55W T8)
2"
Summary of Contents for Certikin CUV110N