3 - DISPLAY
BOTTOM
31
The bottom line with 8mm (0.31”) digits can be set to display:
height - percentage - off - level
The percentage mirrors the input signal: minimum signal (4mA) is 0%,
maximum signal (20mA) is 100%.
TOP
32
The top line with 26mm (1”) digits can be set to display:
level - height - percentage
The percentage mirrors the input signal: minimum signal (4mA) is 0%,
maximum signal (20mA) is 100%.
BARGRAPH
33
The bargraph (piegraph) displayed at operator level is percentage-wise
related to the input signal: minimum signal is 0% (setup 53) and maximum
signal is 100% (setup 54).
With this function, the bargraph can be enabled / disabled.
Following selections are available:
OFF - ON
The functions below will only effect the optional LED-backlight.
BACKLIGHT
(OPTION)
34
If a LED backlight has been supplied, the color can be selected.
Following selections are available:
OFF - GREEN - AMBER
BRIGHTNESS
(OPTION)
35
The density of the backlight can be set in following range:
1 - 5
One is minimum and five is maximum brightness.
4 - POWER MANAGEMENT
When used with the internal battery option, the user can expect reliable measurement over a long
period of time. The F070-A has several smart power management functions to extend the battery life
time significantly. Two of these functions can be set:
LCD NEW
41
The calculation of the display-information influences the power
consumption significantly. When the application does not require a fast
display update, it is
strongly advised
to select a slow refresh rate.
Please understand that NO information will be lost; the input signal will be
processed and the output signal will be generated in the normal way.
The following can be selected:
Fast - 1 sec - 3 sec - 15 sec - off.
Example battery life-time:
battery life-time with a FAST update: about 3 years.
battery life-time with a 1 sec update: about 5 years.
Note:
after a button has been pressed by the operator - the display
refresh rate will always switch to FAST for 30 seconds. When "OFF" is
selected, the display will be switched off after 30 seconds and will be
switched on as soon as a button has been pressed.
BATTERY-MODE
42
The unit has two modes: operational or shelf.
After "shelf" has been selected, the unit can be stored for several years; it
will not process the sensor signal; the display is switched off but all
settings are stored. In this mode, power consumption is extremely low.
To wake up the unit again, press the SELECT-key twice.