ScopeMeter
®
Test Tool
How to Use the Test Tool
25
4. Use the cursor and
E
to:
a. Select
on A
. Observe that the highlight jumps to the present measurement.
b. Select the
A dc
measurement.
c. Select a current probe sensitivity that matches the connected current probe. See
.
The display shows the screen in
.
Figure 10. Meter Screen
Note
To change the current probe sensitivity later, select another type of measurement (for
example, Vdc) and then select Amps again to see the sensitivity menu.
Relative Meter Measurements
A relative measurement displays the present measurement result relative to a defined reference
value. The following example shows how to perform a relative voltage measurement.
First obtain a reference value:
1. Press
M
to show the METER key labels.
2. Measure a voltage to use as a reference value.
3. Press
2
to set RELATIVE to
ON
. ON is highlighted.
This stores the reference value as reference for subsequent measurements. Observe the
ADJUST REFERENCE soft key (
3
) that enables you to adjust the reference value.
1.888.610.7664
sales@GlobalTestSupply.com
Fluke-Direct