background image

2635A-RF900USB 
Instruction Sheet

 

Base Station Modem  

The Modem is connected to the PC as the base 

station. To set up this modem:   
1.

 

Connect the Modem to a free USB port on the PC 

using the supplied USB cable.  

2.

 

The Windows “Found New Hardware Wizard” 

will appear on the PC. Click the “Next” button to 

start the driver installation.  

3.

 

Depending on the version of Windows, select 

either the “Install from a specific list or location” 

or “Search for a suitable driver” option, then click 

“Next”.  

4.

 

Verify the MaxStream CD is inserted. Check 

“Search removable media (CD-ROM…)” or 

“CD-ROM drives” box, and then click the “Next” 

button.  

5.

 

If a “Windows Logo Testing” alert box pops up, 

click “Continue Anyway”.  

6.

 

Click the “Next”button again if necessary to 

accept the selected driver.  

7.

 

Click the “Finish” button.  

8.

 

Repeat steps 2 through 7 to install the next driver.  

9.

 

Connect the supplied antenna to the Modem. 

Remote Station  

Set up a 2635A-RF900 Serial RS-232 Modem and 
connect to the Hydra Data Logger as described in its 
own instruction sheet.  

Operation 

Start the Hydra software and turn the Hydra Data 
Logger power on.  
 
Connect through the Hydra software as if using a 
standard RS-232 connection. Basic line-of-site range 
is approximately 1500 ft. (450 m). The range varies 
with antenna height. 
 
The Modem will operate in its default factory setting 
as an accessory to the Hydra Series. Refer to the 
manufacturer’s instructions and supplied software for 
operating the Modem in other applications.  
 
To reset the Modem to its factory settings, push the 
Reset Switch located on the Antenna-side of the 
Modem.  

Specifications  

Performance  

Indoor/Urban Range:  

Up to 1500 ft (450 m)  

Outdoor LOS Range:  

Up to 7 miles (11 km) w/ dipole  

                                            antenna  
Serial Data Throughput:   9600 bps  
RF Baud Rate:  

10,000 bps  

Transmit Power Output:   140 mW (21.5 dBm)  
Receiver Sensitivity:  

-110 dBm  

General  

Frequency:  

902-928 MHz  

Spread Spectrum:  

Frequency Hopping, Wide band  

                                           FM modulator  
Network Topology:  

Peer-to-Peer, Point-to-multipoint,  

                                           Point-to-Point, Multi-drop  
Channel Capacity:  

7 hop sequences share 25          

                                           frequencies  
Serial Data Interface:  

USB  

I/O Data Rate:  

Software selectable 1200 -  

                                           57600 bps  

Power Requirements  

Supply Voltage:  

USB bus-powered or 5-12 V dc       
external  

Transmit Current:  

215 mA  

Receive Current: 

85 mA  

Physical Properties  

Enclosure:  

7.1 oz (200 g), extruded  
aluminum, black anodized  

Enclosure Size:  

2.75 in x 5.50 in x 1.124 in  
(7.90 cm x 13.90 cm x 3.80 cm)  

Operating Temperature:   0 to 70 

°

C (commercial)  

Antenna  

Type: 

½ wave dipole whip, 6.75 in 
(17.1 cm), 2.1 dBi Gain  

Not licensed for operation outside of the United 

States. 

 

LIMITED WARRANTY AND LIMITATION OF LIABILITY 

This Fluke product will be free from defects in material and 
workmanship for 90 days from the date of purchase. This warranty 
does not cover fuses, disposable batteries, or damage from 
accident, neglect, misuse, alteration,contamination, or abnormal 
conditions of operation or handling. Resellers are not authorized to 
extend any other warranty on Fluke’s behalf. To obtain service 
during the warranty period, contact your nearest Fluke authorized 
service center to obtain return authorization information, 
then send the product to that Service Center with a description of 
the problem. 

THIS WARRANTY IS YOUR ONLY REMEDY. NO OTHER WARRANTIES, 
SUCH AS FITNESS FOR A PARTICULAR PURPOSE, ARE EXPRESSED 
OR IMPLIED. FLUKE IS NOT LIABLE FOR ANY SPECIAL, INDIRECT, 
INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES, ARISING 
FROM ANY CAUSE OR THEORY. 

Since some states or countries do not allow the exclusion or 
limitation of an implied warranty or of incidental or consequential 
damages, this limitation of liability may not apply to you. 
 
Fluke Corporation 
P.O. Box 9090 
Everett, WA 98206-9090 
U.S.A. 

 
Fluke Europe B.V. 
P.O. Box 1186 
5602 BD Eindhoven 
The Netherlands 

11/99 