Options
PROFINET IO (Communication Option 1)
53
8.7.3. Parameter Setting
The parameter setting of a connected pyrometer happens
via “record data” sets. The I/O
module allows diagnostics message to be locked or released. Once all parameter settings are
performed, the I/O device signals that it is ready to send cyclic productive data.
8.7.3.1. Pyrometer parameters
Certain pyrometer characteristics are parameterizable during the configuration. The parameters
of the pyrometer substitute are used to set the overall settings of the PROFINET I/O node.
Some of the setting are used in the module as default settings and can be optionally overwritten
within the module configuration.
Parameter
Description
Setting
Temperature unit
Set the temperature unit
Celsius
Fahrenheit
Color mode
1 , 2 color
Slope
* 1000 (0.9
900)
850 … 1150
Emissivity
* 1000 (0.9
900)
100 … 1100
Transmissivity
* 1000 (1.0
1000)
100 … 1100
Sensor offset
-
200 … +200
Sensor gain
800 … 1200
Averaging time
* 0.1s (1s
10)
0 …3000
Valley hold time
* 0.1s (1s
10)
0 …3000
Peak hold time
* 0.1s (1s
10)
0 …3000
Setpoint relay
in °C /°F
dev. range min. max
Deadband
1 …99
Decay rate
0 …9999
Relay alarm output control
normally open,
normally closed,
permanently open,
permanently closed.
Laser control
off / on / flashing/ trigger
Panel lock
locked / unlocked
Analog output mode
Set output mode
0 … 20 mA / 4 … 20 mA
Bottom temperature of output
Set bottom temperature of
analog output
0…9999°C /°F
Top temperature of output
Set top temperature of analog
output
0…9999°C /°F
8.7.3.2. Profinet alarm behavior
Parameter
Description
Setting
Message diagnostics alarm
The diagnostics information of
pyrometer is not transferred to
the PROFINET IO controller
message inactive
is transferred to the PROFINET
IO controller
message active
Message process alarm
The process alarm of pyrometer
is not transferred to the
PROFINET IO controller
message inactive
is transferred to the PROFINET
IO controller
message active
Behavior on module fault
set process data to zero,
set process data to last value
8.7.4. Structure of the input/output data
8.7.4.1. Pyrometer module input data
The input data length is 23 Byte.