The i400s-EL (the Product) is an ac current clamp that is compatible with 

Fluke 173x Power Loggers and 174x Power Quality Loggers.

How to Contact Fluke

To contact Fluke, call one of the following telephone numbers:
•  Technical Support USA: 1-800-44-FLUKE (1-800-443-5853)
•  Calibration/Repair USA: 1-888-99-FLUKE (1-888-993-5853)
•  Canada: 1-800-36-FLUKE (1-800-363-5853)
•  Europe: +31 402-675-200
•  Japan: +81-3-6714-3114
•  Singapore: +65-6799-5566
•  China: +86-400-921-0835
•  Brazil:  +55-11-3530-8901
•  Anywhere in the world: +1-425-446-5500

Or, visit Fluke’s website at 

www.fluke.com

.

To register your product, visit 

http://register.fluke.com

.

To view, print, or download the latest manual supplement, visit  

http://us.fluke.com/usen/support/manuals

.

PN 4974033

April 2018

© 2018 Fluke Corporation. All rights reserved.  

All product names are trademarks of their respective companies. 

Product specifications are subject to change without notice.

Safety Information

Warning

 identifies conditions and procedures that are dangerous to 

the user. A Caution identifies conditions and procedures that can cause 

dameage to the Product or the equipment under test.



 

Warning

To prevent electrical shock, fire, or personal injury:

• Read all safety information before you use the Product.
• Do not alter the Product and use only as specified, or the 

protection supplied by the Product can be compromised.

• Comply with local and national safety codes. Use personal 

protective equipment (approved rubber gloves, face protection, 

and flame-resistant clothes) to prevent shock and arc blast 

injury where hazardous live conductors are exposed.

• Do not exceed the Measurement Category (CAT) rating of the 

lowest rated individual component of a Product, probe, or 

accessory.

• Before each use, examine the Product. Look for cracks or 

missing pieces of the clamp housing or output cable insulation. 

Also look for loose or weakened components. Carefully 

examine the insulation around the jaws.

• Use caution around bare conductors or bus bars. To prevent 

electrical shock, do not touch the conductor.

• Hold the Product behind the tactile barrier.
• Do not touch voltages >30 V ac rms, 42 V ac peak, or 60 V dc.
• Do not use the Product around explosive gas, vapor, or in 

damp or wet environments.

• Do not use the Product if it is altered or damaged.
• Do not make connections on hazardous live conductors in 

damp or wet environments.

• Limit operation to the specified measurement category, voltage, 

or amperage ratings.

Measurement Considerations

Observe the following guidelines when making measurements (see 

Table 1):
•  Center the conductor inside the Product.
•  Make sure the Product is perpendicular to the conductor.
•  For optimal reading, make sure the conductor is positioned between 

the alignment marks on the jaws of the Product.

•  Avoid taking measurements close to other current-carrying 

conductors.

Symbols 

The table below is a list of symbols used on the Product and in this 

document.

Symbol

Description

WARNING - RISK OF DANGER. Consult user documentation.

WARNING. HAZARDOUS VOLTAGE. Risk of electric shock.

 

Consult user documentation.

Double Insulated

Application around and removal from uninsulated hazardous live 

conductors is permitted.

Measurement Category III is applicable to test and measuring circuits 

connected to the distribution part of the building’s low-voltage MAINS 

installation.

Measurement Category IV is applicable to test and measuring 

circuits connected at the source of the building’s low-voltage MAINS 

installation.

Conforms to European Union directives.

Certified by CSA Group to North American safety standards.

This product complies with the WEEE Directive marking 

requirements. The affixed label indicates that you must not discard 

this electrical/electronic product in domestic household waste. 

Product Category: With reference to the equipment types in the 

WEEE Directive Annex I, this product is classed as category 9 

“Monitoring and Control Instrumentation” product. Do not dispose of 

this product as unsorted municipal waste.