Installation
ScanIR3
21
5.3
Wiring
5.3.1
Overview
Prior to making any wiring connections ensure that AC power is off!
The processor box provides power and communication to the linescanner. For the processor box there
are several output modules available offering analog or digital signals to the central control system see
section 6.2
, page 35. The processor box can be mounted 10 m (33 ft) away from the scanner
with the standard scanner cable length, longer cables are available on request. The scanner cable
between the linescanner and the processor box needs to be protected from mechanical damage. The
cable withstands ambient temperatures up to 180°C (356°F).
Figure 8: Opened Processor Box
Output Modules
Fiber Optic /
RJ45 Ethernet Converter
(optional)
Power Supply
Scanner Head Cable
AC Mains
to be connected
Field wiring for the
Output Modules
Bus Coupler