background image

TOOL REQUIRED:

  

J 39200 Digital Multimeter or equivalent 
 
The following bench check may be used to simulate operation on a vehicle. Use the 
bench check to verify operation of a CS-144 generator that has been repaired. 

1.

 

Mount generator in suitable test stand according to test stand manufacturer's 
instructions. Test stand must be capable of driving generator at 

6,500 RPM.

  

Generator Bench Check 

 

 

2.

 

Make connections as shown in Figure above. Be sure carbon pile is turned off. 
Ground polarity of generator and 

battery

 must be same. Battery must be fully 

charged. Use a 

30-500 ohm

 resistor between battery and "L" terminal of 

generator.  

3.

 

Slowly increase generator speed and observe voltage using J 39200. 

Important

  

 

The 

battery

 must be fully charged when making this test.  

 

The engine must be run at 

2500 RPM

 and at ambient temperature. 