background image

General Specifications 

Media Access 

10BASE-T, 100BASE-TX, 1000BASE-T (IEEE 802.3), and PoE (IEEE 802.3af) 

Cable Tests 

Pair lengths, opens, shorts, splits, crossed, straight through, Wireview

TM

 cable ID 

 

Tone Generator 

IntelliTone digital tone: [500 KHz]  
Analog tones: [400Hz, 1KHz] 

 

 

UI Interface 

B&W, 2”x 1” display,  Link LED 

UI Control / Data Entry  

Five push-buttons for selection of icons and navigation of menus 

Power Button  

On/Off  

 

 

Ports 

(2) RJ45s: network test port, loop-back wire map port  

Application Port  

Mini-USB 

 

 

Battery  

4 AA batteries 4 AA batteries or optional Lithium Ion battery pack with 15VDC 
1.2A AC adaptor accessory 

Physical Security 

Kensington Lock  

Warranty 

One year 

Mechanical Electrical Specifications 

Weight  

10 oz. with 4 AA Alkaline batteries  
8.4 oz. with 4 AA LI batteries 

Dimensions 

5.3” height x 3.1” width x 1.3” depth  
13.3cm height x 8cm width x 3.2cm depth 

RJ-45 Network Port  

Designed to withstand a maximum of 100V 

Security 

Operational Security 

IEEE 802.1X option for network authentication 

Environment Specifications 

Operating Temperature 

10 – 40 degrees C 

Storage Temperature 

-20 to 60  degrees C 

Operating Humidity 

95% relative humidity (non-condensing) 

Vibration Requirements 

Meets requirements for MIL-PRF-28800F for Class 2 random 
vibration 

Connection To Public Telephone 
Network 

Should never be connected to the public telephone network 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for LinkRunner Pro

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...strument download and view reports and other useful function Safety To register your LinkRunner Pro or to obtain a keycode for a purchased option go to www flukenetworks com register and enter your na...

Page 3: ...jury follow these guidelines Do not use this product if it is damaged Before using the product inspect the case Look for cracked or missing plastic Do not operate the product around explosive gas vapo...

Page 4: ...to see how LinkRunner Pro can help you get the job done Common Questions Is this a good cable use open cable testing and a Wireview TM Office Locator Where does this cable go use toner function or Wi...

Page 5: ...e screen PING screen and LLDP EDP CDP screen The reports must be viewed on the LinkRunner Connect PC application Packet Reflector Screen optional feature Enables packet reflector mode which allows the...

Page 6: ...ws Indicates which buttons are active 6 Highlighted function is the active function While a function is active you can scroll to other functions Press the center button to select a new function 7 Acti...

Page 7: ...This screen is displayed if LinkRunner Pro has successfully linked and 802 1X has been detected and authenticated Good cable Unknown cable Split cable Shorted cable Open cable If the RJ 45 Ethernet ca...

Page 8: ...tes that the wire map calibration is in progress When the calibration is completed the display will show the home screen Indicates that a patch cable was not connected between the LAN and MAP ports wh...

Page 9: ...found PING will display Duplicate IP addresses found is shown as follows See the configuration for procedures to set up PING IP addresses LLDP CDP EDP The LLDP CDP EDP function displays the switch ad...

Page 10: ...sts Use the Configuration screen to set up the parameters Saving Reports Allows you to save the report summary information which contains the current Home screen PING screen and LLDP EDP CDP screen Sa...

Page 11: ...the center button to save You can configure 802 1X security settings using the LinkRunner Connect PC application The unit will not power off in PING switch discovery IntelliTone or reflect modes or wh...

Page 12: ...e selection button to save Editing the IP name Press the down arrow key to move the cursor to the IP name field Press the selection button center To enter an IP name move right to each character by us...

Page 13: ...ll thru the report numbers By default the names are Report01 Report04 Editing the report name Using the down arrow key move down to the report name Press the selection button center To edit the report...

Page 14: ...n MAC and IP addresses swaps the source destination MAC address only Blank no swap packet is sent out as it was received The factory default conditions for your LinkRunner Pro are Match FLUKE and Swap...

Page 15: ...apter LRPRO LION Contacting Fluke Networks Sales Service and Support Centers To order accessories or get the location of the nearest Fluke Networks distributor or service center visit the Fluke Networ...

Page 16: ...Security Kensington Lock Warranty One year Mechanical Electrical Specifications Weight 10 oz with 4 AA Alkaline batteries 8 4 oz with 4 AA LI batteries Dimensions 5 3 height x 3 1 width x 1 3 depth 1...

Page 17: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 18: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: