External Features - Connections, Buttons, and the LED 

1.

 

RJ-45 LAN port 

2.

 

RJ-45 MAP port (cable testing) 

3.

 

Power Button 
   

Power off

 – press and hold 

   

Backlight

 – press once briefly 

4.

 

USB port  

5.

 

Selection buttons 
  - 

Up/Down

 arrows navigate the selections and adjust values 

  - 

Left/Right

 arrows show additional information and choices 

  - 

Select

 center button to edit a selection or toggle a value 

6.

 

Link indicator LED 

7.

 

Kensington lock (location on back of LinkRunner Pro) 
 

Note

: To calibrate the wire map function, use a short patch cable and connect it 

between the LAN (1) and MAP (2) port connectors on the top of the LinkRunner. 
Press and hold the left arrow selection button and turn 

on

 the LinkRunner. 

1

2

7

3

5

4

6

 

 

Count on LinkRunner Pro for Answers! 

First connect an RJ-45 cable from the network hub or wall plate to the LinkRunner Pro LAN port. Check the following 
list of questions and associated answers to see how LinkRunner Pro can help you get the job done.

 

Common Questions 

 

Is this a good cable?

  

- use open cable testing and a Wireview

TM

 Office Locator 

 

Where does this cable go?  

- use toner function or Wireview

TM

 Office Locator 

 

Is this cable hooked up to anything? 

- use Home screen  

 

Is this an active Ethernet port? 

- use Home screen, check for Link and frame utilization 

 

What speed/duplex is this device configured for? 

- use Home screen, check speed/duplex 

 

Can I establish Gigabit link to the network? 

- use Home screen, check for speed 

 

Can I DHCP? 

- configure LinkRunner Pro for DHCP, check for link and PING 

 

Can I see traffic from this connection? 

- use Home screen 

 

Is the PC NIC OK? 

- use Home screen, check for Link 

 

Can I PING? 

- use PING screen 

 

Do I have network connectivity? 

- use PING (Router, DNS, DHCP and custom list) 

 

What slot and port am I on? 

- use LLDP, CDP, EDP 

 

Can I use it for throughput testing? 

- use Reflector screen 

 

Can I connect to an 802.1X port?

 

- use  Configuration screen and LinkRunner Connect application

 

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for LinkRunner Pro

Page 1: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Page 2: ...strument download and view reports and other useful function Safety To register your LinkRunner Pro or to obtain a keycode for a purchased option go to www flukenetworks com register and enter your na...

Page 3: ...jury follow these guidelines Do not use this product if it is damaged Before using the product inspect the case Look for cracked or missing plastic Do not operate the product around explosive gas vapo...

Page 4: ...to see how LinkRunner Pro can help you get the job done Common Questions Is this a good cable use open cable testing and a Wireview TM Office Locator Where does this cable go use toner function or Wi...

Page 5: ...e screen PING screen and LLDP EDP CDP screen The reports must be viewed on the LinkRunner Connect PC application Packet Reflector Screen optional feature Enables packet reflector mode which allows the...

Page 6: ...ws Indicates which buttons are active 6 Highlighted function is the active function While a function is active you can scroll to other functions Press the center button to select a new function 7 Acti...

Page 7: ...This screen is displayed if LinkRunner Pro has successfully linked and 802 1X has been detected and authenticated Good cable Unknown cable Split cable Shorted cable Open cable If the RJ 45 Ethernet ca...

Page 8: ...tes that the wire map calibration is in progress When the calibration is completed the display will show the home screen Indicates that a patch cable was not connected between the LAN and MAP ports wh...

Page 9: ...found PING will display Duplicate IP addresses found is shown as follows See the configuration for procedures to set up PING IP addresses LLDP CDP EDP The LLDP CDP EDP function displays the switch ad...

Page 10: ...sts Use the Configuration screen to set up the parameters Saving Reports Allows you to save the report summary information which contains the current Home screen PING screen and LLDP EDP CDP screen Sa...

Page 11: ...the center button to save You can configure 802 1X security settings using the LinkRunner Connect PC application The unit will not power off in PING switch discovery IntelliTone or reflect modes or wh...

Page 12: ...e selection button to save Editing the IP name Press the down arrow key to move the cursor to the IP name field Press the selection button center To enter an IP name move right to each character by us...

Page 13: ...ll thru the report numbers By default the names are Report01 Report04 Editing the report name Using the down arrow key move down to the report name Press the selection button center To edit the report...

Page 14: ...n MAC and IP addresses swaps the source destination MAC address only Blank no swap packet is sent out as it was received The factory default conditions for your LinkRunner Pro are Match FLUKE and Swap...

Page 15: ...apter LRPRO LION Contacting Fluke Networks Sales Service and Support Centers To order accessories or get the location of the nearest Fluke Networks distributor or service center visit the Fluke Networ...

Page 16: ...Security Kensington Lock Warranty One year Mechanical Electrical Specifications Weight 10 oz with 4 AA Alkaline batteries 8 4 oz with 4 AA LI batteries Dimensions 5 3 height x 3 1 width x 1 3 depth 1...

Page 17: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com...

Page 18: ...service in house repair center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE IN...

Reviews: