OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
3-28
Using the Measurement Cursor
You can use the cursor on the OTDR trace to measure
distances and losses along the cabling. The cursor position
and readouts are stored with saved results.
As you move the cursor, the tester calculates averages
around the mark and cursor positions. This reduces the
effects of noise on measurements.
To use the cursor, do the following:
1
If the navigational cue above the softkey labels does
not say
O
Pan,
P
Cursor,
press
E
until it does
.
2
Use
C
Next Event
/
Previous Event
or
K
N
to move
the cursor to a starting point on the trace. Pressing
K
or
N
sets the direction for the
C
softkey
.
3
Press
D
Set Mark
to set the mark; then use
K
N
or
C
Next Event
/
Previous Event
to move the cursor to
the desired ending point.
The following readouts appear on the screen:
Note
To change between
∆
dB
and
∆
dB/km
/
∆
dB/kft
press
F
from the
OTDR TRACE
screen; then
select
MARKER DELTA MODE
from the
OTDR
FUNCTIONS
menu.
•
∆
m
or
∆
ft
: The distance between the cursor and
the mark.
•
∆
dB
: The difference in the power levels (in
decibels) between the cursor and the mark.
•
∆
dB/km
or
∆
dB/kft
: Power loss (in decibels) that
would occur over 1 km (1000 m) or 1 kft (1000 ft)
of cable based on the loss between the cursor
and the mark.
4
Press
D
Clear Mark
to clear the mark.
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...