Using the Visual Fault Locator
Using the VFL
7
7-
3
1
Clean the connectors on the patch cord, if used, and
the fiber to be tested.
2
Connect the fiber directly to the tester’s VFL port or
connect using the patch cord.
3
Turn on the VFL as follows:
•
Press
D
VFL
from the
HOME
screen.
or
•
Press
F
; then select
Visual Fault Locator
.
4
To toggle between continuous wave and pulse
modes, press
B
.
5
To turn the VFL off and on, press
D
.
6
Look for the glow to locate fibers or faults, as shown
in Figure 7-2.
Tip
: To more quickly locate the VFL's light at a patch
panel, view the light indirectly by holding a white
card or paper in front of the fiber connector emitting
the light.
Note
The locator’s light may not be visible through
dark-colored fiber jackets.
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...