OF-500 OptiFiber Certifying OTDR
Technical Reference Handbook
3-22
Looking at OTDR Test Results
The tester offers three different views of OTDR test
results: a summary, an event table, and an OTDR trace.
Reading the SUMMARY Screen
The
SUMMARY
screen, which appears when the test is
finished, is described in Table 3-2.
Table 3-2. OTDR SUMMARY Screen Features
Item Description
PASS/FAIL
PASS
: All test results are within limits.
FAIL
: One or more test result exceeds the limits. See the OTDR trace or the event table for additional
information.
WARNING
The value could not be reliably determined. These values are usually preceded by a "<" or ">" (less than
or greater than) symbol. This may occur if the fiber is too long, the signal is weak, or events are too close
together to distinguish losses. In many cases, the
OTDR DETAILS
screens show causes of the warning.
Press
C
View Details
to see these screens.
FIBER LENGTH
The length of the fiber in the cabling. If the measured length seems wrong, check the index of refraction
on the
Cable
tab in Setup. The length does not include launch and receive fibers if launch fiber
compensation is enabled.
Tip:
In some cable types, some or all of the fibers may be longer than the cable jacket and some fibers
may be longer than others in the same cable. To adjust the length measurements to represent cable
jacket length, change the index of refraction until the measured length matches the jacket length.
-continued-
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...