Using the OTDR
Looking at OTDR Test Results
3
3-25
A
Wavelength for the trace and the
End
setting on the
Job
tab in
SETUP
. If the test ran at two wavelengths,
press
A
to switch wavelengths. You can set the
wavelengths on the
OTDR
tab in Setup.
B
Magnification factors for the trace. See “Zooming the
Trace” on page 3-29.
C
The distance (
m
or
ft
) and the power loss (
dB
) between
the cursor and the measurement marker (
M
).
D
OTDR plot grid. You can enable or disable the grid on
the
OTDR
tab in
SETUP
.
E
PASS/FAIL
status appears if the cursor is on an event.
The status may refer to the event or the fiber segment
before the event. If the event looks ok, press
C
View
Details
from the
EVENT TABLE
screen or the
SUMMARY
screen to see results for the segment.
F
Press
E
to change the arrow keys’ function from
moving the cursor to zooming to moving the trace if
trace overlay is active (see page 3-29). The navigational
cue above the softkey labels describes the arrow keys’
current function.
G
Key for setting and clearing the measurement cursor.
See “Using the Measurement Cursor” on page 3-28.
H
Moves the cursor to the next event on the trace. If you
use
K
to move the cursor,
C
changes to
Previous
Event
and moves the cursor to the previous event.
I
Displays the event table.
J
For dual-wavelength tests, press
A
to switch
wavelengths.
K
Event information appears if the cursor is on an event.
Otherwise, the distance to the cursor is shown.
L
Scale for the distance along the cabling under test.
Tip:
The distance scale represents the distance along the
fiber, which may be different from the distance along
the cable jacket. To adjust the length measurements
to represent cable jacket length, change the index of
refraction until the measured length matches the
jacket length.
M
Measurement marker and cursor. See “Using the
Measurement Cursor” on page 3-28.
N
Decibel scale for the OTDR backscatter.
Figure 3-13. OTDR Trace Screen (cont.)
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...