Using the OTDR
Looking at OTDR Test Results
3
3-37
Table 3-4. Event Types (cont.)
Event Possible
Causes and Solutions
END
The end of the cabling.
The tester identifies the end of the cabling as the point where the backscatter stops.
The tester does not measure the loss of END events. Note that a very high-loss event,
such as a sharp bend, can appear to be the end of the cabling.
Also see
N/A
in Table 3-3.
Sorting Events
You can sort the event table in ascending or descending
order by the items in a column. For example, you could
sort by the loss values in a wavelength column to put the
events with the highest loss at the top of the table. By
default, the table is sorted in ascending order by event
location. The table returns to this order when you exit
the
EVENT TABLE
screen.
To sort the event table, use
K
N
to highlight a column
heading; then press
B
Sort Field
. Pressing
B
again
sorts the table in the opposite order.
Summary of Contents for OF-500 OptiFiber
Page 12: ...OF 500 OptiFiber Technical Reference Handbook x ...
Page 18: ...OF 500 OptiFiber Technical Reference Handbook xvi ...
Page 27: ...Getting Acquainted Powering the Tester 1 1 9 ajt20f eps Figure 1 1 Battery Pack Features ...
Page 29: ...Getting Acquainted Verifying Operation 1 1 11 ajt56f eps Figure 1 2 Removing the Module ...
Page 46: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 1 28 ...
Page 136: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 4 6 ...
Page 192: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 6 48 ...
Page 254: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook 11 36 ...
Page 256: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 272: ...B 14 OF 500 OptiFiber Certifying OTDR Technical Reference Handbook ...
Page 274: ...OF 500 OptiFiber Certifying OTDR Technical Reference Handbook C 2 ...
Page 282: ...OF 500 OptiFiber Technical Reference Handbook 8 ...