Vertical flanged machines – vertiSWEEP
Measure using vertiSWEEP
l
Center the laser beam.
Note
vertiSWEEP is the default measurement mode for vertically mounted machines.
The alternative Static clock measurement mode may be accessed by tapping (
1
)
in screen below.
l
Position the shafts such that sensor and laser are both at the '0' reference mark pos-
ition.
l
Use
or
and select the direction in which the shafts will be rotated. Once
the direction to rotate the shafts is selected, measurement is activated and the letter '
M
'
(
1
) appears and also
(
2
) becomes active.
l
Tap either '
M
' or
then rotate the shafts through an angle greater than 360°.
l
After rotating the shafts through the required angle, tap
(
1
) to display coupling
results. Tap
(
2
)to display shimming corrections.