Note
If the measurements have a high standard deviation [>0.05 mm (>2 thou)] res-
ulting from say bearing play, stiff coupling or radial play in coupling, a hint sug-
gesting the use of Static measurement mode appears on the screen. In this case,
the measurement mode should be changed to Static measurement.
l
(1)
Flange correction in 0-6 direction
l
(2)
Flange correction in 3-9 direction
l
(3)
Bolt position
l
(4)
Shimming values
l
(5)
Coupling gap and offset in the 0-6 direction
ROTALIGN touch EX