Both the sensor (
3
) and laser (
2
) should be at the same height, as low as possible, yet high
enough for the beam to clear the coupling flange. They should also visually appear to be rota-
tionally aligned to each other.
Make the final adjustments, loosening the brackets slightly if necessary, then rotating them,
and re-tightening.
In some cases, if the coupling is large enough, a coupling bolt can be removed and the laser
beam shot through the bolt hole, in order to avoid protruding radially beyond the coupling's
outer diameter (O.D.).
Both sensor and laser should be at the same height, as low as possible, yet just high enough
for the beam to clear the coupling flange. They should also visually appear to be rotationally
aligned to each other.
ROTALIGN touch EX