Move simulator
As the name suggests, the Move simulator is used to simulate shim values and horizontal
movement corrections that are required to correct the alignment condition. The simulator
takes into account the shim thickness available and the amount by which the machines can be
physically moved.
Note
Move simulator can be used on a single plane only (either
V
ertical or
H
orizontal). Sim-
ulation is possible for the current (or "as left") measurement only. And the simulation
may be carried out in 2D or 3D view.
The Move simulator is initiated from the results screen. After taking a measurement, display
the results in either 2D or 3D and on a single plane only.
Tap 'Move simulator' (
1
).
Tap
to increase movement step value or
to decrease step value (
1
). The step value
ranges from 0.025 mm – 1.0 mm for metric units and 1.0 thou – 40.0 thou for imperial units.
Tap machine feet pair to be simulated. A light blue cursor appears on the selected feet pair
(
2
).
With the cursor on the selected feet pair, tap
to move the machine downwards (in
V
ertical view) or towards viewer (in
H
orizontal view) by the movement step value factor. Tap-
ping
moves the machine upwards (in
V
ertical view) or away from viewer (in
H
orizontal
view) [
3
] by the movement step value factor. Carry out the simulation while observing the
78
Version:2.3
On-board help
Summary of Contents for PRUFTECHNIK ROTALIGN touchEX
Page 1: ...ROTALIGN touch EX On board help ...
Page 2: ...ROTALIGN touch EX On board help Version 2 3 Edition 03 2020 Part No DOC 52 202 EN ...
Page 11: ...This page intentionally left blank ...
Page 13: ...12 Version 2 3 On board help ...
Page 43: ...42 Version 2 3 On board help ...
Page 137: ...136 Version 2 3 On board help ...