ThermoView® Series
Users Manual
32
Scope of delivery
•
Enclosure with cooling jacket and Zinc Selenide window
•
Air barrier flange
•
2x cable glands
Environment
Rating
IP67
Ambient temperature
200°C (392°F)
with 6 l/min (1.5 gal/min) of water at 20°C (68°F) inlet
temperature and 6 bar (87 PSI) for front air barrier
Air pressure
recommended: 4 to 6 bar (58 to 87 PSI)
Mechanical
Construction
stainless steel, AISI 316L, polished
Weight
13 kg (29 lb), without camera
Cable gland
M12x1.5, threaded holes on the rear flange
The Zinc Selenide window has a transmission factor of 0.96 meaning it transmits
96% of the radiation before it gets to the camera. For correct temperature
readings, that transmission factor needs to be considered.
Cooling
By forcing water circulation, it is possible to maintain cooled internal housing temperatures. It
helps to verify the flow capacity needed and cooling water temperature before proceeding with
the installation. Before installation, it is also necessary to verify the environmental temperature
and install the housing at the correct distance from the heating source.
Air Barrier
The flange for window cleaning uses ventilation to create an air barrier on the front of the
housing in order to prevent any deposits of dust on the outer surface of the window. For proper
use, it is always advisable to filter the compressed air with a dedicated filter that is equipped
with a gauge pressure regulator. For proper installation, it is necessary to check the
environmental temperature and place the air filter group at the correct distance from the heat
source.
For optimal performance of air barrier, it is recommended positioning the
enclosure in a horizontal position or decline angle. Positioning the
enclosure with the air barrier vertically may affect its performance!
Noise level emissions produced by air barrier may exceed recommend
safe exposure levels!
Installation
•
Locate 2x M4 screws on camera
•
Place conduction plate onto camera as shown, making sure to line up holes on camera with
hole and slot on conduction plate.
•
Install 2x M4 screws and secure conduction plate onto camera.
•
Place the housing internal rail onto conduction plate as shown on first slot, making sure to
place rail with correct orientation by having rail securing hole at rear.
•
Secure rail to conduction plate by installing 2x screws (truss), 4x curved washers (2x per
screw), and 2x flat washers. Insert the screws until each screw contacts with curved
washer; curved washers will be compressed once camera is installed in enclosure.
•
Note
: For cameras with remote focus place rail as shown with one screw in each slot.
•
Secure ground cable to camera as shown (color of cable/ring terminals used for display
only).