20
TS100 PRO Cable Fault Finder
Users Guide
How to Clean the Tester
To clean the display, use lens cleaner and a soft, lint-
free cloth. To clean the case, use a soft cloth that is
moist with water or water and a weak soap. Do not
use petroleum-based or chlorinated cleaning agents.
Caution
Do not use CRC Cable Clean
®
or any similar
chlorinated solvent on the test set. Doing so
will damage the tester.
Accessories
Table 4 shows the accessories available for the TS100
PRO tester. For the latest list of accessories, visit the
Fluke Networks website.
Specifications
Table 4. Accessories
Description
Fluke Networks
Model Number
Test leads, ABN with piercing-pin-clips
LEAD-ABNP-100
Test leads with alligator clips
LEAD-ALIG-100
Test leads with angled bed of nails
LEAD-ABN-100
TS100 PRO pouch with belt clip
CASE-TS-100
Maximum Length
8,000 feet (2,438 meters) on certain cable types, 4,000 feet (1,220 meters) on most cable
types, and 500 feet (152 meters) on cables with high loss. The tester shows
-
Err
if the cable is
too long to be correctly measured.
Representative
Maximum Cable
Length
8,000 feet (2,438 meters): CAT-3 Twisted Pair
8,000 feet (2,438 meters): CAT-5 Twisted Pair
6,000 feet (1,830 meters): 12/2 AC Wire
3,000 feet (900 meters): RG-6/U TV Coax
1,500 feet (457 meters): RG-174/U Coax
Minimum Length
No minimum length. Minimum non-zero reading is 2 feet or1 meter
Length Accuracy
±2 feet (±0.6 m) for cables less than 10 feet (3 m)
±5 feet (±2 m) for cables longer than 10 feet (3 m) and shorter than 200 feet (60 m)
±3%, ±5 feet (±2 m) for cables longer than 200 feet (60 m)
Distance to Bridge
Tap