background image

8

EASY CONNECTION SYSTEM INSTALLATION

This section only applies to Fluval Aquariums with Fluval External filter and “EasyConnect” System. 

If your Aquarium Kit is equipped with a Fluval Internal filter, go directly to “Fluval Filter installation” 

chapter.

Installing water intake/output with “EasyConnect” 
system

(Intake/output fittings are included in the filter packaging)

Some Fluval Aquarium models feature the new and innovative “EasyConnect” 

system, which allows the direct connection of the tank to the external filter 

through the bottom glass by means of special fittings. Normally, the same 

type of connection is achieved through specially-made devices, which are 

complex and require the intervention of expert technicians. On the contrary, 

in a few minutes the “EasyConnect” system can be easily and safely installed, 

giving your aquarium the most professional and clean solution.

Before proceeding, identify and count all parts required by referring 

to the exploded view in the side illustration. If any part is missing, do 

not proceed with the installation and contact your local supplier.
Before proceeding, check stems (A) for the presence of all 3 rubber 

rings (C). Do not proceed with the installation if one of the rubber 

rings (C) is missing and contact your local supplier.

Locate the 2 openings in the tank bottom glass and assure that the 

corresponding openings in the cabinet are aligned with them. The 2 openings 

in the tank bottom glass are complete with factory installed special plastic 

fittings,  which  must  never  be  removed,  turned  or  loosened  and  with  two 

sealing plugs (P) and (Q). The 

output group should be installed in 

the opening (O), whereas the 

intake group should be installed in 

the opening (I).

Once the output/intake 

groups are installed, do 

not shift the tank with 

respect to the cabinet as this 

may damage the output/intake 

devices and the glass tank.
Do not force, loosen or turn the 

factory-installed special fittings 

on tank openings (I) and (O).

Output system installation

1.  Manually unscrew plug (P) and remove plug (Q) from opening (O) (Pict. 1).

 IMPORTANT

: keep plugs (P) and (Q) for any future use.

2.  Slip connector stem (A) fully through opening (O) until it stops (Pict. 2).
3.  Open the cabinet. Screw and tighten the ring nut (R) onto the bottom end of stem (A) (Pict. 3).
4.  Insert the ouput nozzle (N) into one end of output stem (B).
5.  Insert output stem (B) onto connector stem (A) (Pict. 4).
6.  Regulate the height of output nozzles according to your requirement by sliding outlet stem 

(B) along connector stem (A).

INTAKE 

GROUP

OUTPUT 

GROUP

Output 

Nozzle (N)

Output 

Stem (B)

Intake 

Strainer (S)

Connector 

Stem (A)

Ring Nut 

(R)

TANK BOTTOM SEALING PLUGS

P

Q

Plugs

Connector Stem’s 

Rubber Rings (C)

I

O

Locate the 2 openings (I) and (O) in the 

tank bottom glass and the corresponding 

holes in the cabinet

Pict. 1

Q

P

Summary of Contents for Roma Aquarium LED

Page 1: ...and Aquarium Mode d emploi Rampe d clairage DEL et bac d aquarium Manual de instrucciones Tanque de acuario con luminaria LED Gebrauchsanleitung LED Strip Light und Aquarium Roma Aquarium LED Vicenza...

Page 2: ...______________________________________________ 40 Table des mati res PI CES DE L AQUARIUM FLUVAL AVEC CLAIRAGE DEL_________________________________________ 13 MESURES DE S CURIT IMPORTANTES___________...

Page 3: ...autorizado con garant a 30 SERVICIO A LA CLIENTELA____________________________________________________________________ 40 Inhaltsverzeichnis FLUVAL AQUARIUM LED TEILE_________________________________...

Page 4: ...AND FOLLOW ALL SAFETY INSTRUCTIONS and all important notices on the appliance before using Failure to do so may result in loss of life and or injury or damage to the unit 2 DANGER To avoid possible el...

Page 5: ...isconnect Always unplug an appliance from an outlet when not in use WARNING Be sure you unplug the LED driver from the power outlet just switching off the lights with the APP is NOT enough because it...

Page 6: ...our aquarium ie with planters or algae scrapers Never use toxic or aggressive substances to clean your aquarium such as household detergents SETTING UP YOUR FLUVAL AQUARIUM For proper installation and...

Page 7: ...ll of water rocks decorations or gravel have not been considered FLUVAL ROMA LED MODEL TANK DIMENSIONS HEIGHT OF FILLING up to the max water level line WEIGHT OF AQUARIUM FULL WITH WATER Fluval Roma 9...

Page 8: ...enings in the tank bottom glass and assure that the corresponding openings in the cabinet are aligned with them The 2 openings in the tank bottom glass are complete with factory installed special plas...

Page 9: ...east 5 cm from the gravel bottom at all times to prevent it from sucking gravel or sand and ensure that no decorations block the passage of water Ornaments and rocks should be positioned while the aqu...

Page 10: ...its connector Pict 9 also shows the connection of 2 lighting units on a Venezia 350 Only use the supplied drivers for these light units 3 Place the aluminium beam B2 and the front and rear access lid...

Page 11: ...he Strip Light from power supply before any maintenance operation WARNING Be sure you unplug the LED driver from the power outlet just switching off the lights with the APP is NOT enough because it do...

Page 12: ...e negligence improper installation tampering abuse or commercial use The warranty does not cover wear and tear or parts which have not been adequately or correctly maintained Failure of less than 5 of...

Page 13: ...a m and 4 00 p m Eastern Standard Time Ask for Customer Service UK Customer Services Rolf C Hagen UK Ltd California Drive Whitwood Ind Est Castleford West Yorkshire WF10 5QH Help Line Number 01977 521...

Reviews: